ECC or Buildings Branch
This is honeywells catalog of parts.
COMBUSTION
CATALOG
Honeywell Thermal Solutions
Table of Contents
ii 70-8911
7800 Series Product Selection Matrix............................. 1
7800 Series Product Selection for legacy and competitor
replacements ................................................................ 20
Commercial/Industrial Combustion Controls
7800 Series Burner Controls......................................... 21
EC7820 Primary Control Meeting European Community Timings...21
EC7830; EC7850; RM7830; RM7850 Programming Control
Meeting European Community Timings...........................................22
RM7800 Programmers....................................................................23
RM7800 Programmers with VPS.....................................................24
RM7823; EC7823 Flame Switch......................................................25
RM7824 On-Off Primary Control.....................................................26
RM7838A Manual Start Industrial Primary Control with Purge........27
RM7838B, C Manual Start Industrial Programmers........................28
RM7838B, C Manual Start Industrial Programmers with VPS.........29
RM7840 Programmers....................................................................30
RM7840 Programmers with VPS.....................................................31
RM7845 Programmers....................................................................32
RM7885 Manual Start Industrial Primary Control............................32
RM7888 PLC Adaptable Primary Control........................................33
RM7890 On-Off Primary Control with VPS......................................34
RM7890; EC7890 On-Off Primary Controls.....................................35
RA890 Replacement Options using RM/EC7890 Components......36
RM7895; EC7895 On-Off Primary Control with Prepurge................37
RM7896 On-Off Primary Control with Pre- and Post-Purge.............38
RM7897 Automatic Primary Control with Programmable Post-
Purge...............................................................................................39
RM7898 On-Off Primary Control with VPS......................................40
Q7800 22 Terminal Universal Wiring Subbases..............................41
S7800 Keyboard Display Module....................................................43
S7800 Keyboard Display Module for VP Programming....................44
S7800 Keyboard Display Module 4-LINE LCD................................45
S7810A Data ControlBus™ Module................................................46
S7810M ModBus Module................................................................46
S7820 Remote Reset Module.........................................................47
ST7800 Plug In Purge Timer...........................................................48
7800 Series Accessories or Parts...................................................49
7800 SERIES Flame Signal Amplifiers............................................50
Flame Amplifier Accessories............................................................50
R8001 SLATE Combustion System............................... 51
SOLA Controllers........................................................... 52
SOLA™ Hydronic Control................................................................52
SOLA™ Steam Control...................................................................53
S7999D SOLA™ System Operator Interface...................................55
PM7910 Program Module................................................................56
SOLA™ Accessories or Parts.........................................................56
Flame Detectors............................................................ 57
C7012 Solid State Purple Peeper® Ultraviolet Flame Detector........57
C7027; C7044 Minipeeper Ultraviolet Flame Detector....................59
C7035 Minipeeper Ultraviolet Flame Detector.................................60
C7061 Dynamic Self-Check Ultraviolet Flame Detector..................61
C7076 Adjustable Sensitivity Ultraviolet Flame Detector.................62
C7961 Dynamic Self-checking Solid State Ultraviolet Flame
Detector...........................................................................................63
C7915 Infrared Flame Detector.......................................................64
Optical Flame Detector Accessories or Parts..................................65
Pilot Burners.................................................................. 66
Q179A Flame Rectifier Gas Pilots...................................................66
Ignition Transformers..................................................... 67
Q624 Solid State Ignition Transformer.............................................67
ET401A1 Ignition Transformer.........................................................68
Ignition Transformer Accessories or Parts.......................................69
Firing Rate Motors......................................................... 70
M9484D, E, F; M9494D, F Modutrol® IV Motors..............................70
Diaphragm Gas Valves.................................................. 72
V48A; V88A Diaphragm Gas Valves................................................72
V88J High Temperature Diaphragm Gas Valves.............................. 74
V4943/V8943A On/Off Diaphragm Gas Valves...............................75
V4943/V8943B, C, N Single Stage Pressure Regulating Valves...... 76
V4944/V8944B, C, L, N Two Stage Pressure Regulating Gas
Valves..............................................................................................78
Diaphragm Gas Valve Replacement Parts or Accessories..............80
Gas Valve Actuators....................................................... 81
Selection Chart: V5055 and V5097 Industrial Gas Valves with
V4055 or V4062 Fluid Power Actuators...........................................81
V4055A, B, D, E On-Off Fluid Power Gas Valve Actuator................83
V4062 Off-Lo-Hi Fluid Power Gas Valve Actuators..........................85
Fluid Actuator Accessories and Parts..............................................86
Industrial Gas Valves..................................................... 87
V5055 Industrial Gas Valves............................................................87
V5097 Integrated Valve Train...........................................................91
Integrated Valve Train Pipe Adapters...............................................93
V5055/5097 Replacement Parts or Accessories.............................93
Pilot Gas Valves............................................................. 94
V4046C; V8046C Pilot Gas Valves..................................................94
Solenoid Gas Valves...................................................... 95
V4295; V8295 Solenoid Gas Valves................................................95
Servo Regulated Gas Valves......................................... 98
V4730C; V4734C; V8730C Gas/Air Servo Regulated Gas Valves...98
V4730C; V4734C; V8730C Accessories and Parts........................ 100
Venturi Mixing Unit........................................................101
Venturi Mixing Unit......................................................................... 101
Pressure Switches....................................................... 102
C6097 Pressure Switch................................................................. 102
Pressure and Limit Controllers..................................... 103
L404F Pressuretrol® Controllers..................................................... 103
L404T, V Oil Pressuretrol® Limit Controllers................................... 105
L4079 Pressuretrol® Limit Controllers............................................ 106
L408J Vaporstat® Controllers......................................................... 107
L91 Proportional Pressuretrol® Controllers.................................... 108
Pressure Controls and Limits Accessories......................................110
Testers and Demonstrators........................................... 111
A7800 Tester...................................................................................111
A7800 and DSP2672 Replacement Parts......................................111
Demonstrators or Trainers..............................................................111
SOLA Demonstrators.....................................................................112
Flame Simulator.............................................................................112
SLATE Demo Kit.............................................................................113
Industrial Flame Monitoring
Signal Processors.........................................................114
P531; P532 3-channel, Signal Processors.....................................114
600U Flame Rod Signal Processor................................................114
P522 Signal Processor with 2 Channels and Keypad.....................115
WATCHDOGIIIBE Flare Stack Signal Processor............................116
S256BE Flare Stack Viewing Head................................................116
700 Signal Processor with 1 Channel.............................................117
All-in-One Viewing Head and Processor.......................118
All-in-One Viewing Head and Processor.........................................118
Viewing Heads..............................................................119
700 and 800 Series Viewing Heads...............................................119
S55xBE Series Viewing Heads..................................................... 120
GHE Igniter System..................................................... 121
GHE Igniter System Accessoires................................................... 121
GHE Igniter System - GHE1-3....................................................... 121
GHE Igniter System - GHE2-5....................................................... 121
IFM Accessories.......................................................... 122
Industrial Flame Monitoring Accessories....................................... 122
Fiberoptics - FASA......................................................................... 126
Fiberoptics - FASA-INT.................................................................. 126
Fiberoptic System........................................................ 126
General Information
Approval Bodies........................................................... 129
Table of Contents
70-8911 iii
Reference Information................................................. 130
Date Code..................................................................................... 130
Horsepower Ratings...................................................................... 130
Product literature............................................................................ 130
NEMA Standard Classification Code for Flame Safeguard
Enclosures..................................................................................... 131
IP Standard Classification............................................................. 131
Capacities...................................................................................... 132
Power & Heat................................................................................. 133
Btu Contents of Fuels.................................................................... 133
Commercial/Industrial Combustion Conversion Factors................ 133
Buying Rebuilts? Proceed with CAUTION................... 134
Lab Trainers................................................................. 135
Ordering Information for Training Materials.................. 137
Terms and Conditions.................................................. 137
Model Index
iv 70-8911
Numerics
600U Flame Rod Signal Processor....................................................114
700 and 800 Series Viewing Heads....................................................119
700 Signal Processor with 1 Channel.................................................117
7800 Series Accessories or Parts.......................................................49
7800 SERIES Flame Signal Amplifiers................................................50
A
A7800 and DSP2672 Replacement Parts..........................................111
A7800 Tester.......................................................................................111
All-in-One Viewing Head and Processor.............................................118
B
Btu Contents of Fuels........................................................................ 133
C
C6097 Pressure Switch..................................................................... 102
C7012 Solid State Purple Peeper® Ultraviolet Flame Detector............57
C7027; C7044 Minipeeper Ultraviolet Flame Detector........................59
C7035 Minipeeper Ultraviolet Flame Detector.....................................60
C7061 Dynamic Self-Check Ultraviolet Flame Detector......................61
C7076 Adjustable Sensitivity Ultraviolet Flame Detector.....................62
C7915 Infrared Flame Detector...........................................................64
C7961 Dynamic Self-checking Solid State Ultraviolet Flame Detector.63
Capacities.......................................................................................... 132
Commercial/Industrial Combustion Conversion Factors.................... 133
D
Date Code.......................................................................................... 130
Demonstrators or Trainers..................................................................111
Diaphragm Gas Valve Replacement Parts or Accessories..................80
E
EC7820 Primary Control Meeting European Community Timings.......21
EC7830; EC7850; RM7830; RM7850 Programming Control Meeting
European Community Timings............................................................22
ET401A1 Ignition Transformer.............................................................68
F
Fiberoptics - FASA............................................................................. 126
Fiberoptics - FASA-INT...................................................................... 126
Flame Amplifier Accessories................................................................50
Flame Simulator.................................................................................112
Fluid Actuator Accessories and Parts..................................................86
G
GHE Igniter System Accessoires....................................................... 121
GHE Igniter System - GHE1-3........................................................... 121
GHE Igniter System - GHE2-5........................................................... 121
H
Horsepower Ratings.......................................................................... 130
I
Ignition Transformer Accessories or Parts...........................................69
Industrial Flame Monitoring Accessories........................................... 122
Integrated Valve Train Pipe Adapters...................................................93
IP Standard Classification................................................................. 131
L
L91 Proportional Pressuretrol® Controllers......................................... 108
L404F Pressuretrol® Controllers......................................................... 103
L404T, V Oil Pressuretrol® Limit Controllers....................................... 105
L408J Vaporstat® Controllers............................................................. 107
L4079 Pressuretrol® Limit Controllers................................................ 106
M
M9484D, E, F; M9494D, F Modutrol® IV Motors..................................70
N
NEMA Standard Classification Code for Flame Safeguard
Enclosures......................................................................................... 131
O
Optical Flame Detector Accessories or Parts......................................65
P
P522 Signal Processor with 2 Channels and Keypad.........................115
P531; P532 3-channel, Signal Processors.........................................114
PM7910 Program Module....................................................................56
Power & Heat..................................................................................... 133
Pressure Controls and Limits Accessories..........................................110
Product literature................................................................................ 130
Q
Q179A Flame Rectifier Gas Pilots.......................................................66
Q624 Solid State Ignition Transformer.................................................67
Q7800 22 Terminal Universal Wiring Subbases..................................41
R
RA890 Replacement Options using RM/EC7890 Components..........36
RM7800 Programmers.........................................................................23
RM7800 Programmers with VPS.........................................................24
RM7823; EC7823 Flame Switch..........................................................25
RM7824 On-Off Primary Control.........................................................26
RM7838A Manual Start Industrial Primary Control with Purge............27
RM7838B, C Manual Start Industrial Programmers.............................28
RM7838B, C Manual Start Industrial Programmers with VPS.............29
RM7840 Programmers.........................................................................30
RM7840 Programmers with VPS.........................................................31
RM7845 Programmers.........................................................................32
RM7885 Manual Start Industrial Primary Control................................32
RM7888 PLC Adaptable Primary Control............................................33
RM7890; EC7890 On-Off Primary Controls.........................................35
RM7890 On-Off Primary Control with VPS..........................................34
RM7895; EC7895 On-Off Primary Control with Prepurge....................37
RM7896 On-Off Primary Control with Pre- and Post-Purge.................38
RM7897 Automatic Primary Control with Programmable Post-Purge..39
RM7898 On-Off Primary Control with VPS..........................................40
S
S55xBE Series Viewing Heads.......................................................... 120
S256BE Flare Stack Viewing Head....................................................116
S7800 Keyboard Display Module.........................................................43
S7800 Keyboard Display Module 4-LINE LCD....................................45
S7800 Keyboard Display Module for VP Programming........................44
S7810A Data ControlBus™ Module....................................................46
S7810M ModBus Module....................................................................46
S7820 Remote Reset Module..............................................................47
S7999D SOLA™ System Operator Interface.......................................55
Selection Chart: V5055 and V5097 Industrial Gas Valves with V4055
or V4062 Fluid Power Actuators...........................................................81
SLATE Demo Kit.................................................................................113
SOLA Demonstrators.........................................................................112
SOLA™ Accessories or Parts..............................................................56
SOLA™ Hydronic Control....................................................................52
SOLA™ Steam Control........................................................................53
ST7800 Plug In Purge Timer...............................................................48
V
V48A; V88A Diaphragm Gas Valves....................................................72
V88J High Temperature Diaphragm Gas Valves.................................. 74
V4046C; V8046C Pilot Gas Valves......................................................94
V4055A, B, D, E On-Off Fluid Power Gas Valve Actuator....................83
V4062 Off-Lo-Hi Fluid Power Gas Valve Actuators..............................85
V4295; V8295 Solenoid Gas Valves....................................................95
V4730C; V4734C; V8730C Accessories and Parts............................ 100
V4730C; V4734C; V8730C Gas/Air Servo Regulated Gas Valves.......98
V4943/V8943A On/Off Diaphragm Gas Valves...................................75
Model Index
70-8911 v
V4943/V8943B, C, N Single Stage Pressure Regulating Valves.......... 76
V4944/V8944B, C, L, N Two Stage Pressure Regulating Gas Valves..78
V5055/5097 Replacement Parts or Accessories.................................93
V5055 Industrial Gas Valves................................................................87
V5097 Integrated Valve Train...............................................................91
Venturi Mixing Unit............................................................................. 101
W
WATCHDOGIIIBE Flare Stack Signal Processor................................116
70-8911 1
7800 Series Product Selection Matrix
7800 Series Product Selection Matrix
Product Selection Matrix for CE Sequence
Primary/Programmer Relay Modules:
For 230 Vac nominal applications —
Fuel Burner Type Relay Module Type
Single Atmospheric with fan EC7820
Combination or single On/Off Controlled Power Burner EC7830
Combination or single Full Modulation Power Burner EC7850
For 120 Vac nominal applications —
Fuel Burner Type Relay Module Type
Combination or single On/Off Controlled Power Burner RM7830
Combination or single Full Modulation Power Burner RM7850
Use the following pages to select the following required devices:
Relay Module, 1 per burner
Subbase, 1 per relay module
Purge Timer Card, 1 per relay module
Flame Amplifier, 1 per relay module
Some products are available only through Authorized Flame Safeguard Wholesalers and/or Distributors.
Use the following pages to select the following optional devices:
Keyboard Display module, up to 1 mounted to relay module, remote as desired network and ControlBus™ modules to service selected relays
Miscellaneous, as required to complete installation.
2 70-8911
7800 Series Product Selection Matrix
PRODUCT SELECTION MATRIX FOR EC7820 PROGRAMMER RELAY MODULES:
M15516G
SELECT A
SUBBASE
SELECT A
PURGE
CARD
SELECT
OPTIONAL
COMPONENTS
KEYBOARD
DISPLAY
MODULE
COMMUNICATIONS
MISCELLANEOUS
SELECT A
RELAY
MODULE
220-240 VAC 50/60 HZ
EC7820A1026
DESCRIPTION
ONE IGNITION ATTEMPT
O.S. NO.
Q7800A1005
Q7800B1003
Q7800B1011
DESCRIPTION
PANEL MOUNT
BURNER/WALL MOUNT
BURNER/WALL MOUNT WITH 3 KNOCKOUTS
O.S. NO.
ST7800A1005
ST7800A1013
ST7800A1021
ST7800A1039
ST7800A1047
ST7800A1054
ST7800A1062
DESCRIPTION
TIMING: 2 SECOND
TIMING: 7 SECOND
TIMING: 10 SECOND
TIMING: 30 SECOND
TIMING: 40 SECOND
TIMING: 60 SECOND
TIMING: 90 SECOND
O.S. NO.
ST7800A1070
ST7800A1088
ST7800A1096
ST7800A1104
ST7800A1112
ST7800A1120
ST7800A1138
ST7800A1146
DESCRIPTION
TIMING: 2.5 MINUTE
TIMING: 4 MINUTE
TIMING: 6 MINUTE
TIMING: 9 MINUTE
TIMING: 12 MINUTE
TIMING: 15 MINUTE
TIMING: 22 MINUTE
TIMING: 30 MINUTE
O.S. NO.
R7847A1025
R7847A1033
R7847A1074
R7847A1082
R7847B1023
R7847B1031
R7847B1064
R7847B1072
R7849A1015
R7849A1023
R7861A1026
R7861A1034
R7886A1001
DESCRIPTION
1 SECOND FFRT
2 SECOND FFRT
1 SECOND FFRT
2 SECOND FFRT
1 SECOND FFRT
2 SECOND FFRT
1 SECOND FFRT
2 SECOND FFRT
1 SECOND FFRT
2 SECOND FFRT
2 SECOND FFRT
1 SECOND FFRT
2 SECOND FFRT
CHECKING
NONE
NONE
NONE
NONE
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
NONE
NONE
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
O.S. NO. DESCRIPTION
S7800A1001 2-LINE ENGLISH LANGUAGE
S7800A1142 2-LINE ENGLISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A1167 2-LINE SPANISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A2142 4-LINE ENGLISH/SPANISH/FRENCH (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
O.S. NO.
S7810A1009
S7810M1029
DESCRIPTION
DATA CONTROLBUS® MODULE (IF NO KEYBOARD DISPLAY IS USED)
MODBUS MODULE - CE APPROVAL
O.S. NO.
S7820A1007
203541
221729
50023821-001
50023821-002
221818A
221818C
204729A
204729C
DESCRIPTION
REMOTE RESET MODULE
DATA CONTROLBUS CONNECTOR, 5-WIRE
DUST COVER, RELAY MODULE
KEYBOARD DISPLAY MODULE COVER, NEMA 4,
KEYBOARD DISPLAY MODULE COVER, NEMA 4, CLEAR
WITH RESET BUTTON
EXTENSION CABLE, DISPLAY 5FT (1524MM)
EXTENSION CABLE, DISPLAY 10FT (3048MM)
4-line Keyboard Display module cover NEMA4 w/o reset
4-line Keyboard Display module cover NEMA4 with reset
USE WITH
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*
C7027, C7035
C7027, C7035
C7061A, F**
C7061A, F**
C7076A
SELECT
A FLAME
AMPLIFIER
* FLAME ROD LEADWIRE RUNS GREATER THAN 50FT (1524 CM) OR PARALLEL C7012 A,C.
** EC APPLICATIONS REQUIRE A 220-240 VAC TO 120 VAC, STEP DOWN, 10VA TRANSFORMER.
1.)
2.)
3.)
4.)
5.)
70-8911 3
7800 Series Product Selection Matrix
PRODUCT SELECTION MATRIX FOR EC/RM7830 PROGRAMMER RELAY MODULES:
M15517H
SELECT A
SUBBASE
SELECT A
PURGE
CARD
SELECT
OPTIONAL
COMPONENTS
KEYBOARD
DISPLAY
MODULE
COMMUNICATIONS
MISCELLANEOUS
SELECT A
RELAY
MODULE
220-240 VAC 50/60 HZ
EC7830A1033
EC7830A1066
120VAC 50/60 HZ
RM7830A1003
RM7830A1029
O.S. NO.
Q7800A1005
Q7800B1003
Q7800B1011
DESCRIPTION
PANEL MOUNT
BURNER/WALL MOUNT
BURNER/WALL MOUNT WITH 3 KNOCKOUTS
O.S. NO.
ST7800A1005
ST7800A1013
ST7800A1021
ST7800A1039
ST7800A1047
ST7800A1054
ST7800A1062
DESCRIPTION
TIMING: 2 SECOND
TIMING: 7 SECOND
TIMING: 10 SECOND
TIMING: 30 SECOND
TIMING: 40 SECOND
TIMING: 60 SECOND
TIMING: 90 SECOND
O.S. NO.
ST7800A1070
ST7800A1088
ST7800A1096
ST7800A1104
ST7800A1112
ST7800A1120
ST7800A1138
ST7800A1146
DESCRIPTION
TIMING: 2.5 MINUTE
TIMING: 4 MINUTE
TIMING: 6 MINUTE
TIMING: 9 MINUTE
TIMING: 12 MINUTE
TIMING: 15 MINUTE
TIMING: 22 MINUTE
TIMING: 30 MINUTE
O.S. NO.
R7847A1025
R7847A1033
R7847A1074
R7847A1082
R7847B1023
R7847B1031
R7847B1064
R7847B1072
R7849A1015
R7849A1023
R7861A1026
R7861A1034
R7886A1001
DESCRIPTION
1 SECOND FFRT
2 SECOND FFRT
1 SECOND FFRT
2 SECOND FFRT
1 SECOND FFRT
2 SECOND FFRT
1 SECOND FFRT
2 SECOND FFRT
1 SECOND FFRT
2 SECOND FFRT
2 SECOND FFRT
1 SECOND FFRT
2 SECOND FFRT
CHECKING
NONE
NONE
NONE
NONE
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
NONE
NONE
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
DESCRIPTION
POST-PURGE 2 SECONDS
POST-PURGE 30 SECONDS
POST-PURGE 15 SECONDS
O.S. NO.
S7810A1009
S7810M1029
DESCRIPTION
DATA CONTROLBUS® MODULE (IF NO KEYBOARD DISPLAY IS USED)
MODBUS MODULE - CE APPROVAL
O.S. NO.
S7820A1007
203541
221729
50023821-001
50023821-002
221818A
221818C
204729A
204729C
DESCRIPTION
REMOTE RESET MODULE
DATA CONTROLBUS CONNECTOR, 5-WIRE
DUST COVER, RELAY MODULE
KEYBOARD DISPLAY MODULE COVER, NEMA 4
KEYBOARD DISPLAY MODULE COVER, NEMA 4, CLEAR WITH
RESET BUTTON
EXTENSION CABLE, DISPLAY 5FT (1524MM)
EXTENSION CABLE, DISPLAY 10FT (3048MM)
4-line Keyboard Display module cover NEMA4 w/o reset
4-line Keyboard Display module cover NEMA4 with reset
USE WITH
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*
C7027, C7035
C7027, C7035
C7061A, F**
C7061A, F**
C7076A
SELECT
A FLAME
AMPLIFIER
* FLAME ROD LEADWIRE RUNS GREATER THAN 50FT (1524 CM) OR PARALLEL C7012 A,C.
** EC APPLICATIONS REQUIRE A 220-240 VAC TO 120 VAC, STEP DOWN, 10VA TRANSFORMER.
1.)
2.)
3.)
4.)
5.)
O.S. NO. DESCRIPTION
S7800A1001 2-LINE ENGLISH LANGUAGE
S7800A1142 2-LINE ENGLISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A1167 2-LINE SPANISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A2142 4-LINE ENGLISH/SPANISH/FRENCH (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
4 70-8911
7800 Series Product Selection Matrix
PRODUCT SELECTION MATRIX FOR EC/RM7850 PROGRAMMER RELAY MODULES:
M15519G
SELECT A
SUBBASE
SELECT A
PURGE
CARD
SELECT
OPTIONAL
COMPONENTS
KEYBOARD
DISPLAY
MODULE
COMMUNICATIONS
MISCELLANEOUS
SELECT A
RELAY
MODULE
220-240 VAC 50/60 HZ
EC7850A1072
EC7850A1080
EC7850A1122
120VAC 50/60 HZ
RM7850A1001
RM7850A1019
O.S. NO.
Q7800A1005
Q7800B1003
Q7800B1011
DESCRIPTION
PANEL MOUNT
BURNER/WALL MOUNT
BURNER/WALL MOUNT WITH 3 KNOCKOUTS
O.S. NO.
ST7800A1005
ST7800A1013
ST7800A1021
ST7800A1039
ST7800A1047
ST7800A1054
ST7800A1062
DESCRIPTION
TIMING: 2 SECOND
TIMING: 7 SECOND
TIMING: 10 SECOND
TIMING: 30 SECOND
TIMING: 40 SECOND
TIMING: 60 SECOND
TIMING: 90 SECOND
O.S. NO.
ST7800A1070
ST7800A1088
ST7800A1096
ST7800A1104
ST7800A1112
ST7800A1120
ST7800A1138
ST7800A1146
DESCRIPTION
TIMING: 2.5 MINUTE
TIMING: 4 MINUTE
TIMING: 6 MINUTE
TIMING: 9 MINUTE
TIMING: 12 MINUTE
TIMING: 15 MINUTE
TIMING: 22 MINUTE
TIMING: 30 MINUTE
O.S. NO.
R7847A1025
R7847A1033
R7847A1074
R7847A1082
R7847B1023
R7847B1031
R7847B1064
R7847B1072
R7849A1015
R7849A1023
R7861A1026
R7861A1034
R7886A1001
DESCRIPTION
1 SECOND FFRT
2 SECOND FFRT
1 SECOND FFRT
2 SECOND FFRT
1 SECOND FFRT
2 SECOND FFRT
1 SECOND FFRT
2 SECOND FFRT
1 SECOND FFRT
2 SECOND FFRT
2 SECOND FFRT
1 SECOND FFRT
2 SECOND FFRT
CHECKING
NONE
NONE
NONE
NONE
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
NONE
NONE
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
DESCRIPTION
POST-PURGE 2 SECONDS
POST-PURGE 30 SECONDS
POST-PURGE 15 SECONDS
O.S. NO.
S7810A1009
S7810M1029
DESCRIPTION
DATA CONTROLBUS® MODULE (IF NO KEYBOARD DISPLAY IS USED)
MODBUS MODULE - CE APPROVAL
O.S. NO.
S7820A1007
203541
221729
50023821-001
50023821-002
221818A
221818C
204729A
204729C
DESCRIPTION
REMOTE RESET MODULE
DATA CONTROLBUS CONNECTOR, 5-WIRE
DUST COVER, RELAY MODULE
KEYBOARD DISPLAY MODULE COVER, NEMA 4
KEYBOARD DISPLAY MODULE COVER, NEMA 4, CLEAR WITH
RESET BUTTON
EXTENSION CABLE, DISPLAY 5FT (1524MM)
EXTENSION CABLE, DISPLAY 10FT (3048MM)
4-line Keyboard Display module cover NEMA4 w/o reset
4-line Keyboard Display module cover NEMA4 with reset
USE WITH
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*
C7027, C7035
C7027, C7035
C7061A, F**
C7061A, F**
C7076A
SELECT
A FLAME
AMPLIFIER
* FLAME ROD LEADWIRE RUNS GREATER THAN 50FT (1524 CM) OR PARALLEL C7012A,C.
** EC APPLICATIONS REQUIRE A 220-240 VAC TO 120 VAC, STEP DOWN, 10VA TRANSFORMER.
1.)
2.)
3.)
4.)
5.)
O.S. NO. DESCRIPTION
S7800A1001 2-LINE ENGLISH LANGUAGE
S7800A1142 2-LINE ENGLISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A1167 2-LINE SPANISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A2142 4-LINE ENGLISH/SPANISH/FRENCH (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
70-8911 5
7800 Series Product Selection Matrix
PRODUCT SELECTION MATRIX FOR EC/RM7823 FLAME SWITCH RELAY MODULES:
M15520F
SELECT A
SUBBASE
SELECT
OPTIONAL
COMPONENTS
KEYBOARD
DISPLAY
MODULE
COMMUNICATIONS
MISCELLANEOUS
SELECT A
RELAY
MODULE
220-240 VAC 50/60 HZ
EC7823A1004
120VAC 50/60 HZ
RM7823A1016
O.S. NO.
Q7800A1005
Q7800B1003
Q7800B1011
DESCRIPTION
PANEL MOUNT
BURNER/WALL MOUNT
BURNER/WALL MOUNT WITH 3 KNOCKOUTS
O.S. NO.
S7810A1009
S7810M1003
DESCRIPTION
DATA CONTROLBUS® MODULE (IF NO KEYBOARD DISPLAY IS USED)
MODBUS MODULE
O.S. NO.
S7820A1007
S7830A1005
203541
203765
221729
50023821-001
204718B
50023821-002
205321B
221818A
221818C
204729A
204729C
DESCRIPTION
REMOTE RESET MODULE
EXPANDED ANNUNCIATIOR (120 VAC, 50/60 HZ)
DATA CONTROLBUS CONNECTOR, 5-WIRE
REMOTE DISPLAY MOUNTING BRACKET
DUST COVER, RELAY MODULE
KEYBOARD DISPLAY MODULE COVER, NEMA 4
KEYBOARD DISPLAY MODULE COVER, CLEAR
KEYBOARD DISPLAY MODULE COVER, NEMA 4, CLEAR WITH
RESET BUTTON
FLUSH DISPLAY MOUNTING KIT
EXTENSION CABLE, DISPLAY 5FT (1524MM)
EXTENSION CABLE, DISPLAY 10FT (3048MM)
4-line Keyboard Display module cover NEMA4 w/o reset
4-line Keyboard Display module cover NEMA4 with reset
O.S. NO.
R7847A1025
R7847A1033
R7847A1074
R7847A1082
R7847B1023
R7847B1031
R7847B1064
R7847B1072
R7847C1005
R7849A1015
R7849A1023
R7849B1013
R7849B1021
R7851C1008
R7852A1001
R7852B1009
R7861A1026
R7861A1034
R7886A1001
DESCRIPTION ***
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
CHECKING
NONE
NONE
NONE
NONE
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®***
DYNAMIC SELF-CHECK
NONE
NONE
AMPLICHECK®***
AMPLICHECK®***
DYNAMIC SELF-CHECK
NONE
AMPLICHECK®
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
USE WITH
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
C7012E,F**
C7027, C7035
C7027, C7035
C7027, C7035
C7027, C7035
C7961E,F
C7915
C7915
C7061A, F**
C7061A, F**
C7076A, D
SELECT
A FLAME
AMPLIFIER
1.)
2.)
3.)
4.)
* FLAME ROD LEADWIRE RUNS GREATER THAN 50FT (1524 CM) OR PARALLEL C7012A,C.
** EC APPLICATIONS REQUIRE A 220-240 VAC TO 120 VAC, STEP DOWN, 10VA TRANSFORMER.
*** USING AN AMPLICHECK FLAME AMPLIFIER WITH A NON-SHUTTERCHECK UV SENSOR IS NOT CE APPROVED
O.S. NO. DESCRIPTION
S7800A1001 2-LINE ENGLISH LANGUAGE
S7800A1142 2-LINE ENGLISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A1167 2-LINE SPANISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A2142 4-LINE ENGLISH/SPANISH/FRENCH (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
6 70-8911
7800 Series Product Selection Matrix
PRODUCT SELECTION MATRIX FOR RM7824A 24VDC PRIMARY CONTROL RELAY MODULES:
M15521D
SELECT A
SUBBASE
SELECT
A FLAME
AMPLIFIER
SELECT
OPTIONAL
COMPONENTS
KEYBOARD
DISPLAY
MODULE
COMMUNICATIONS
MISCELLANEOUS
SELECT A
RELAY
MODULE
RM7824A1006 24VDC
O.S. NO.
Q7800A1005
Q7800B1003
Q7800B1011
DESCRIPTION
PANEL MOUNT
BURNER/WALL MOUNT
BURNER/WALL MOUNT WITH 3 KNOCKOUTS
O.S. NO.
R7824C1002
R7851B1000
R7851B1018
R7852A1001
R7852B1009
DESCRIPTION
3.0 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
CHECKING
DYNAMIC SELF-CHECK
AMPLICHECK®
AMPLICHECK®
NONE
AMPLICHECK®
O.S. NO.
S7810A1009
S7810M1003
DESCRIPTION
DATA CONTROLBUS® MODULE (IF NO KEYBOARD DISPLAY IS USED)
MODBUS MODULE
O.S. NO.
S7820A1007
203541
203765
221729
50023821-001
204718B
50023821-002
205321B
221818A
221818C
204729A
204729C
DESCRIPTION
REMOTE RESET MODULE
DATA CONTROLBUS CONNECTOR, 5-WIRE
REMOTE DISPLAY MOUNTING BRACKET
DUST COVER, RELAY MODULE
KEYBOARD DISPLAY MODULE COVER, NEMA 4
KEYBOARD DISPLAY MODULE COVER, CLEAR
KEYBOARD DISPLAY MODULE COVER, NEMA 4, CLEAR WITH
RESET BUTTON
FLUSH DISPLAY MOUNTING KIT
EXTENSION CABLE, DISPLAY 5FT (1524MM)
EXTENSION CABLE, DISPLAY 10FT (3048MM)
4-line Keyboard Display module cover NEMA4 w/o reset
4-line Keyboard Display module cover NEMA4 with reset
USE WITH
C7024E, F
C7927
C7927
C7915
C7915
1.)
2.)
3.)
4.)
O.S. NO. DESCRIPTION
S7800A1001 2-LINE ENGLISH LANGUAGE
S7800A1142 2-LINE ENGLISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A1167 2-LINE SPANISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A2142 4-LINE ENGLISH/SPANISH/FRENCH (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
70-8911 7
7800 Series Product Selection Matrix
PRODUCT SELECTION MATRIX FOR RM7885 MANUAL START PRIMARY RELAY MODULES:
M15522F
SELECT A
SUBBASE
SELECT
OPTIONAL
COMPONENTS
KEYBOARD
DISPLAY
MODULE
COMMUNICATIONS
MISCELLANEOUS
SELECT A
RELAY
MODULE
120VAC 50/60 HZ
RM7885A1015
DESCRIPTION
SEMI AUTOMATIC PRIMARY
O.S. NO.
Q7800A1005
Q7800B1003
Q7800B1011
DESCRIPTION
PANEL MOUNT
BURNER/WALL MOUNT
BURNER/WALL MOUNT WITH 3 KNOCKOUTS
O.S. NO.
S7810A1009
S7810M1003
DESCRIPTION
DATA CONTROLBUS® MODULE (IF NO KEYBOARD DISPLAY IS USED)
MODBUS MODULE
O.S. NO.
S7820A1007
203541
203765
221729
50023821-001
204718B
50023821-002
205321B
221818A
221818C
204729A
204729C
DESCRIPTION
REMOTE RESET MODULE
DATA CONTROLBUS CONNECTOR, 5-WIRE
REMOTE DISPLAY MOUNTING BRACKET
DUST COVER, RELAY MODULE
KEYBOARD DISPLAY MODULE COVER, NEMA 4
KEYBOARD DISPLAY MODULE COVER, CLEAR
KEYBOARD DISPLAY MODULE COVER, NEMA 4, CLEAR WITH
RESET BUTTON
FLUSH DISPLAY MOUNTING KIT
EXTENSION CABLE, DISPLAY 5FT (1524MM)
EXTENSION CABLE, DISPLAY 10FT (3048MM)
4-line Keyboard Display module cover NEMA4 w/o reset
4-line Keyboard Display module cover NEMA4 with reset
O.S. NO.
R7847A1025
R7847A1033
R7847A1074
R7847A1082
R7847B1023
R7847B1031
R7847B1064
R7847B1072
R7847C1005
R7849A1015
R7849A1023
R7849B1013
R7849B1021
R7851C1008
R7852A1001
R7852B1009
R7861A1026
R7861A1034
R7886A1001
DESCRIPTION***
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
CHECKING
NONE
NONE
NONE
NONE
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
DYNAMIC SELF-CHECK
NONE
NONE
AMPLICHECK®
AMPLICHECK®
DYNAMIC SELF-CHECK
NONE
AMPLICHECK®
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
USE WITH
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
C7012E, F
C7027, C7035
C7027, C7035
C7027, C7035
C7027, C7035
C7961E,F
C7915
C7915
C7061A, F
C7061A, F
C7076A, D
SELECT
A FLAME
AMPLIFIER
1.)
2.)
3.)
4.)
* FLAME ROD LEADWIRE RUNS GREATER THAN 50FT (1524 CM) OR PARALLEL C7012A,C.
O.S. NO. DESCRIPTION
S7800A1001 2-LINE ENGLISH LANGUAGE
S7800A1142 2-LINE ENGLISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A1167 2-LINE SPANISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A2142 4-LINE ENGLISH/SPANISH/FRENCH (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
8 70-8911
7800 Series Product Selection Matrix
PRODUCT SELECTION MATRIX FOR RM7888A SPECIAL FUNCTION PRIMARY CONTROL RELAY MODULES:
M15523F
SELECT A
SUBBASE
SELECT
OPTIONAL
COMPONENTS
KEYBOARD
DISPLAY
MODULE
COMMUNICATIONS
MISCELLANEOUS
SELECT A
RELAY
MODULE
120VAC 50/60 HZ
RM7888A1019
RM7888A1027
DESCRIPTION
INDUSTRIAL PRIMARY CONTROL (COMPONENT UL APPROVED)
INDUSTRIAL PRIMARY CONTROL (COMPONENT UL APPROVED)
O.S. NO.
Q7800A1005
Q7800B1003
Q7800B1011
DESCRIPTION
PANEL MOUNT
BURNER/WALL MOUNT
BURNER/WALL MOUNT WITH 3 KNOCKOUTS
O.S. NO.
S7810A1009
S7810M1003
DESCRIPTION
DATA CONTROLBUS® MODULE (IF NO KEYBOARD DISPLAY IS USED)
MODBUS MODULE
O.S. NO.
S7820A1007
203541
203765
221729
50023821-001
204718B
50023821-002
205321B
221818A
221818C
204729A
204729C
DESCRIPTION
REMOTE RESET MODULE
DATA CONTROLBUS CONNECTOR, 5-WIRE
REMOTE DISPLAY MOUNTING BRACKET
DUST COVER, RELAY MODULE
KEYBOARD DISPLAY MODULE COVER, NEMA 4
KEYBOARD DISPLAY MODULE COVER, CLEAR
KEYBOARD DISPLAY MODULE COVER, NEMA 4, CLEAR WITH
RESET BUTTON
FLUSH DISPLAY MOUNTING KIT
EXTENSION CABLE, DISPLAY 5FT (1524MM)
EXTENSION CABLE, DISPLAY 10FT (3048MM)
4-line Keyboard Display module cover NEMA4 w/o reset
4-line Keyboard Display module cover NEMA4 with reset
O.S. NO.
R7847A1025
R7847A1033
R7847A1074
R7847A1082
R7847B1023
R7847B1031
R7847B1064
R7847B1072
R7847C1005
R7849A1015
R7849A1023
R7849B1013
R7849B1021
R7851C1008
R7852A1001
R7852B1009
R7861A1026
R7861A1034
R7886A1001
DESCRIPTION
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
CHECKING
NONE
NONE
NONE
NONE
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
DYNAMIC SELF-CHECK
NONE
NONE
AMPLICHECK®
AMPLICHECK®
DYNAMIC SELF-CHECK
NONE
AMPLICHECK®
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
USE WITH
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
C7012E, F
C7027, C7035
C7027, C7035
C7027, C7035
C7027, C7035
C7961E, F
C7915
C7915
C7061A, F
C7061A, F
C7076A, D
SELECT
A FLAME
AMPLIFIER
1.)
2.)
3.)
4.)
* FLAME ROD LEADWIRE RUNS GREATER THAN 50FT (1524 CM) OR PARALLEL C7012A,C.
O.S. NO. DESCRIPTION
S7800A1001 2-LINE ENGLISH LANGUAGE
S7800A1142 2-LINE ENGLISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A1167 2-LINE SPANISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A2142 4-LINE ENGLISH/SPANISH/FRENCH (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
70-8911 9
7800 Series Product Selection Matrix
PRODUCT SELECTION MATRIX FOR EC/RM7890 ON/OFF PRIMARY CONTROL RELAY MODULES:
M15524G
SELECT A
SUBBASE
SELECT
OPTIONAL
COMPONENTS
KEYBOARD
DISPLAY
MODULE
COMMUNICATIONS
MISCELLANEOUS
SELECT A
RELAY
MODULE
120VAC 50/60 HZ
RM7890A1015
RM7890A1031
RM7890A1056
RM7890A1064‡
RM7890B1014
RM7890B1030
RM7890B1063
EC7890B1028
RM7890B1048
RM7890B1055++
RM7890D1004
DESCRIPTION
4 OR 10 SEC PFEP
30 SECOND PFEP
FOR VALVE PROVING APPLICATIONS
4 OR 10 SEC PFEP
WITH SHUTTER DRIVE
WITH SHUTTER DRIVE AND FULL PFEP
WITH SHUTTER DRIVE
WITH SHUTTER DRIVE
WITH SHUTTER DRIVE - FOR VALVE PROVING APPLICATIONS
WITH SHUTTER DRIVE
INFRARED HEATER ONLY 15 OR 30 PREF
O.S. NO.
Q7800A1005
Q7800B1003
Q7800B1011
DESCRIPTION
PANEL MOUNT
BURNER/WALL MOUNT
BURNER/WALL MOUNT WITH 3 KNOCKOUTS
O.S. NO.
S7810A1009
S7810M1003
S7810M1029
DESCRIPTION
DATA CONTROLBUS® MODULE (IF NO KEYBOARD DISPLAY IS USED)
MODBUS MODULE
MODBUS MODULE - CE APPROVED
O.S. NO.
S7820A1007
203541
203765
221729
50023821-001
204718B
50023821-002
205321B
221818A
221818C
204729A
204729C
DESCRIPTION
REMOTE RESET MODULE
DATA CONTROLBUS CONNECTOR, 5-WIRE
REMOTE DISPLAY MOUNTING BRACKET
DUST COVER, RELAY MODULE
KEYBOARD DISPLAY MODULE COVER, NEMA 4
KEYBOARD DISPLAY MODULE COVER, CLEAR
KEYBOARD DISPLAY MODULE COVER, NEMA 4, CLEAR WITH
RESET BUTTON
FLUSH DISPLAY MOUNTING KIT
EXTENSION CABLE, DISPLAY 5FT (1524MM)
EXTENSION CABLE, DISPLAY 10FT (3048MM)
4-LINE KEYBOARD DISPLAY MODULE COVER NEMA4 W/O RESET
4-LINE KEYBOARD DISPLAY MODULE COVER NEMA4 WITH RESET
O.S. NO.
R7847A1025
R7847A1033
R7847A1074
R7847A1082
R7847B1023
R7847B1031
R7847B1064
R7847B1072
R7847C1005
R7849A1015
R7849A1023
R7849B1013
R7849B1021
R7851C1008
R7852A1001
R7852B1009
R7861A1026
R7861A1034
R7886A1001
DESCRIPTION***
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
CHECKING
NONE
NONE
NONE
NONE
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®****
DYNAMIC SELF-CHECK
NONE
NONE
AMPLICHECK®****
AMPLICHECK®****
DYNAMIC SELF-CHECK
NONE
AMPLICHECK®
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
USE WITH
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
C7012E, F**
C7027, C7035
C7027, C7035
C7027, C7035
C7027, C7035
C7961E, F
C7915
C7915
C7061A, F**
C7061A, F**
C7076A, D
SELECT
A FLAME
AMPLIFIER
1.)
2.)
3.)
4.)
* FLAME ROD LEADWIRE RUNS GREATER THAN 50FT (1524 CM) OR PARALLEL C7012A,C.
** EC APPLICATIONS REQUIRE A 220-240 VAC TO 120 VAC, STEP DOWN, 10VA TRANSFORMER.
*** FFRT FOR CE APPROVED CONTROLS 1 SEC. OR 2 SEC.
**** USING AN AMPLICHECK FLAME AMPLIFIER WITH A NON-SHUTTERCHECK UV SENSOR IS NOT CE APPROVED
‡ CE APPROVED
++ NORTH AMERICAN AND CE APPROVED
O.S. NO. DESCRIPTION
S7800A1001 2-LINE ENGLISH LANGUAGE
S7800A1142 2-LINE ENGLISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A1167 2-LINE SPANISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A2142 4-LINE ENGLISH/SPANISH/FRENCH (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
10 70-8911
7800 Series Product Selection Matrix
PRODUCT SELECTION MATRIX FOR EC/RM7895 ON/OFF WITH PURGE PRIMARY RELAY MODULES:
M15525F
SELECT A
SUBBASE
SELECT
OPTIONAL
COMPONENTS
KEYBOARD
DISPLAY
MODULE
COMMUNICATIONS
MISCELLANEOUS
SELECT A
RELAY
MODULE
220-240 VAC 50/60 HZ
EC7895A1010
EC7895C1000
120VAC 50/60 HZ
RM7895A1014
RM7895A1048
RM7895B1013
RM7895E1002
RM7895E1010
RM7895C1012
RM7895C1020
RM7895D1011
RM7895E1002
RM7895E1010
RM7895A1089
DESCRIPTION
4 OR 10 SEC PFEP
EARLY SPARK TERMINATION
DYNAMIC AIRFLOW SWITCH CHECK
HIGH FLAME SENSOR VOLTAGE FOR IR APPLICATIONS
4-10 SEC PFEP
EARLY SPARK TERMINATION
DYNAMIC AIRFLOW SWITCH CHECK
INFRARED HEATER APPLICATIONS, 15/30 SECOND PFEP
10 SEC PFEP
INTERMITTEND PILOT
O.S. NO.
Q7800A1005
Q7800B1003
Q7800B1011
DESCRIPTION
PANEL MOUNT
BURNER/WALL MOUNT
BURNER/WALL MOUNT WITH 3 KNOCKOUTS
O.S. NO.
S7810A1009
S7810M1003
DESCRIPTION
DATA CONTROLBUS® MODULE (IF NO KEYBOARD DISPLAY IS USED)
MODBUS MODULE
O.S. NO.
S7820A1007
S7830A1005
203541
203765
221729
50023821-001
204718B
50023821-002
205321B
221818A
221818C
204729A
204729C
DESCRIPTION
REMOTE RESET MODULE
EXPANDED ANNUNCIATIOR (120 VAC, 50/60 HZ)
DATA CONTROLBUS CONNECTOR, 5-WIRE
REMOTE DISPLAY MOUNTING BRACKET
DUST COVER, RELAY MODULE
KEYBOARD DISPLAY MODULE COVER, NEMA 4
KEYBOARD DISPLAY MODULE COVER, CLEAR
KEYBOARD DISPLAY MODULE COVER, NEMA 4, CLEAR WITH
RESET BUTTON
FLUSH DISPLAY MOUNTING KIT
EXTENSION CABLE, DISPLAY 5FT (1524MM)
EXTENSION CABLE, DISPLAY 10FT (3048MM)
4-LINE KEYBOARD DISPLAY MODULE COVER NEMA4 W/O RESET
4-LINE KEYBOARD DISPLAY MODULE COVER NEMA4 WITH RESET
INTERRUPTED PILOT
INTERMITTENT PILOT
SELECT A
PURGE
CARD
O.S. NO.
ST7800A1005
ST7800A1013
ST7800A1021
ST7800A1039
ST7800A1047
ST7800A1054
ST7800A1062
DESCRIPTION
TIMING: 2 SECOND
TIMING: 7 SECOND
TIMING: 10 SECOND
TIMING: 30 SECOND
TIMING: 40 SECOND
TIMING: 60 SECOND
TIMING: 90 SECOND
O.S. NO.
ST7800A1070
ST7800A1088
ST7800A1096
ST7800A1104
ST7800A1112
ST7800A1120
ST7800A1138
ST7800A1146
DESCRIPTION
TIMING: 2.5 MINUTE
TIMING: 4 MINUTE
TIMING: 6 MINUTE
TIMING: 9 MINUTE
TIMING: 12 MINUTE
TIMING: 15 MINUTE
TIMING: 22 MINUTE
TIMING: 30 MINUTE
O.S. NO.
R7847A1025
R7847A1033
R7847A1074
R7847A1082
R7847B1023
R7847B1031
R7847B1064
R7847B1072
R7847C1005
R7849A1015
R7849A1023
R7849B1013
R7849B1021
R7851C1008
R7851A1001
R7852B1009
R7861A1026
R7861A1034
R7886A1001
DESCRIPTION***
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
CHECKING
NONE
NONE
NONE
NONE
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
DYNAMIC SELF-CHECK
NONE
NONE
AMPLICHECK®
AMPLICHECK®
DYNAMIC SELF-CHECK
NONE
AMPLICHECK®
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
USE WITH
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
C7012E, F**
C7027, C7035
C7027, C7035
C7027, C7035
C7027, C7035
C7961E, F
C7915
C7915
C7061A, F**
C7061A, F**
C7076A, D
SELECT
A FLAME
AMPLIFIER
1.)
2.)
3.)
4.)
5.)
* FLAME ROD LEADWIRE RUNS GREATER THAN 50FT (1524 CM) OR PARALLEL C7012A,C.
** EC APPLICATIONS REQUIRE A 220-240 VAC TO 120 VAC, STEP DOWN, 10VA TRANSFORMER.
O.S. NO. DESCRIPTION
S7800A1001 2-LINE ENGLISH LANGUAGE
S7800A1142 2-LINE ENGLISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A1167 2-LINE SPANISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A2142 4-LINE ENGLISH/SPANISH/FRENCH (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
70-8911 11
7800 Series Product Selection Matrix
PRODUCT SELECTION MATRIX FOR RM7896 ON/OFF WITH PRE- AND POST-PURGE PRIMARY RELAY MODULES:
M13908B
SELECT A
SUBBASE
SELECT
OPTIONAL
COMPONENTS
KEYBOARD
DISPLAY
MODULE
COMMUNICATIONS
MISCELLANEOUS
SELECT A
RELAY
MODULE
120VAC 50/60 HZ
RM7896A1012
RM7896C1010
RM7896D1019
RM7896D1027
O.S. NO.
Q7800A1005
Q7800B1003
Q7800B1011
DESCRIPTION
PANEL MOUNT
BURNER/WALL MOUNT
BURNER/WALL MOUNT WITH 3 KNOCKOUTS
O.S. NO.
S7810A1009
S7810M1003
DESCRIPTION
DATA CONTROLBUS® MODULE (IF NO KEYBOARD DISPLAY IS USED)
MODBUS MODULE
INTERRUPTED PILOT
INTERMITTENT PILOT
SELECT A
PURGE
CARD
O.S. NO.
ST7800A1005
ST7800A1013
ST7800A1021
ST7800A1039
ST7800A1047
ST7800A1054
ST7800A1062
DESCRIPTION
TIMING: 2 SECOND
TIMING: 7 SECOND
TIMING: 10 SECOND
TIMING: 30 SECOND
TIMING: 40 SECOND
TIMING: 60 SECOND
TIMING: 90 SECOND
O.S. NO.
ST7800A1070
ST7800A1088
ST7800A1096
ST7800A1104
ST7800A1112
ST7800A1120
ST7800A1138
ST7800A1146
DESCRIPTION
TIMING: 2.5 MINUTE
TIMING: 4 MINUTE
TIMING: 6 MINUTE
TIMING: 9 MINUTE
TIMING: 12 MINUTE
TIMING: 15 MINUTE
TIMING: 22 MINUTE
TIMING: 30 MINUTE
O.S. NO.
R7847A1025
R7847A1033
R7847A1074
R7847A1082
R7847B1023
R7847B1031
R7847B1064
R7847B1072
R7847C1005
R7849A1015
R7849A1023
R7849B1013
R7849B1021
R7851C1008
R7851A1001
R7852B1009
R7861A1026
R7861A1034
R7886A1001
DESCRIPTION***
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
CHECKING
NONE
NONE
NONE
NONE
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
DYNAMIC SELF-CHECK
NONE
NONE
AMPLICHECK®
AMPLICHECK®
DYNAMIC SELF-CHECK
NONE
AMPLICHECK®
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
USE WITH
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
C7012E, F
C7027, C7035
C7027, C7035
C7027, C7035
C7027, C7035
C7961E, F
C7915
C7915
C7061A, F
C7061A, F
C7076A, D
SELECT
A FLAME
AMPLIFIER
1.)
2.)
3.)
4.)
5.)
* FLAME ROD LEADWIRE RUNS GREATER THAN 50FT (1524 CM) OR PARALLEL C7012A,C.
O.S. NO.
S7820A1007
S7830A1005
203541
203765
221729
50023821-001
204718B
50023821-002
205321B
221818A
221818C
204729A
204729C
DESCRIPTION
REMOTE RESET MODULE
EXPANDED ANNUNCIATIOR (120 VAC, 50/60 HZ)
DATA CONTROLBUS CONNECTOR, 5-WIRE
REMOTE DISPLAY MOUNTING BRACKET
DUST COVER, RELAY MODULE
KEYBOARD DISPLAY MODULE COVER, NEMA 4
KEYBOARD DISPLAY MODULE COVER, CLEAR
KEYBOARD DISPLAY MODULE COVER, NEMA 4, CLEAR WITH
RESET BUTTON
FLUSH DISPLAY MOUNTING KIT
EXTENSION CABLE, DISPLAY 5FT (1524MM)
EXTENSION CABLE, DISPLAY 10FT (3048MM)
4-LINE KEYBOARD DISPLAY MODULE COVER NEMA4 W/O RESET
4-LINE KEYBOARD DISPLAY MODULE COVER NEMA4 WITH RESET
O.S. NO. DESCRIPTION
S7800A1001 2-LINE ENGLISH LANGUAGE
S7800A1142 2-LINE ENGLISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A1167 2-LINE SPANISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A2142 4-LINE ENGLISH/SPANISH/FRENCH (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
12 70-8911
7800 Series Product Selection Matrix
PRODUCT SELECTION MATRIX FOR RM7897 ON/OFF WITH PRE- AND PROGRAMMABLE POST-PURGE
PRIMARY RELAY MODULES:
M15526H
SELECT A
SUBBASE
SELECT
OPTIONAL
COMPONENTS
KEYBOARD
DISPLAY
MODULE
COMMUNICATIONS
MISCELLANEOUS
SELECT A
RELAY
MODULE
O.S. NO.
Q7800A1005
Q7800B1003
Q7800B1011
DESCRIPTION
PANEL MOUNT
BURNER/WALL MOUNT
BURNER/WALL MOUNT WITH 3 KNOCKOUTS
DESCRIPTION
INTERMITTENT/INTERRUPTED PILOT AND PROOF OF CLOSURE
INTERRUPTED PILOT WITH DELAYED MV2 AND PROOF OF CLOSURE
O.S. NO.
S7810A1009
S7810M1003
DESCRIPTION
DATA CONTROLBUS® MODULE (IF NO KEYBOARD DISPLAY IS USED)
MODBUS MODULE
SELECT A
PURGE
CARD
O.S. NO.
ST7800A1005
ST7800A1013
ST7800A1021
ST7800A1039
ST7800A1047
ST7800A1054
ST7800A1062
DESCRIPTION
TIMING: 2 SECOND
TIMING: 7 SECOND
TIMING: 10 SECOND
TIMING: 30 SECOND
TIMING: 40 SECOND
TIMING: 60 SECOND
TIMING: 90 SECOND
O.S. NO.
ST7800A1070
ST7800A1088
ST7800A1096
ST7800A1104
ST7800A1112
ST7800A1120
ST7800A1138
ST7800A1146
DESCRIPTION
TIMING: 2.5 MINUTE
TIMING: 4 MINUTE
TIMING: 6 MINUTE
TIMING: 9 MINUTE
TIMING: 12 MINUTE
TIMING: 15 MINUTE
TIMING: 22 MINUTE
TIMING: 30 MINUTE
120 VAC 50/60 HZ
RM7897A1002
RM7897C1000
O.S. NO.
R7847A1025
R7847A1033
R7847A1074
R7847A1082
R7847B1023
R7847B1031
R7847B1064
R7847B1072
R7847C1005
R7849A1015
R7849A1023
R7849B1013
R7849B1021
R7851C1008
R7852A1001
R7852B1009
R7861A1026
R7861A1034
R7886A1001
DESCRIPTION
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
CHECKING
NONE
NONE
NONE
NONE
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
DYNAMIC SELF-CHECK
NONE
NONE
AMPLICHECK®
AMPLICHECK®
DYNAMIC SELF-CHECK
NONE
AMPLICHECK®
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
USE WITH
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
C7012E, F
C7027, C7035
C7027, C7035
C7027, C7035
C7027, C7035
C7961E,F
C7915
C7915
C7061A, F
C7061A, F
C7076A, D
SELECT
A FLAME
AMPLIFIER
1.)
2.)
3.)
4.)
5.)
* FLAME ROD LEADWIRE RUNS GREATER THAN 50FT (1524 CM) OR PARALLEL C7012A,C.
O.S. NO.
S7820A1007
S7830A1005
203541
203765
221729
50023821-001
204718B
50023821-002
205321B
221818A
221818C
204729A
204729C
DESCRIPTION
REMOTE RESET MODULE
EXPANDED ANNUNCIATIOR (120 VAC, 50/60 HZ)
DATA CONTROLBUS CONNECTOR, 5-WIRE
REMOTE DISPLAY MOUNTING BRACKET
DUST COVER, RELAY MODULE
KEYBOARD DISPLAY MODULE COVER, NEMA 4
KEYBOARD DISPLAY MODULE COVER, CLEAR
KEYBOARD DISPLAY MODULE COVER, NEMA 4, CLEAR WITH
RESET BUTTON
FLUSH DISPLAY MOUNTING KIT
EXTENSION CABLE, DISPLAY 5FT (1524MM)
EXTENSION CABLE, DISPLAY 10FT (3048MM)
4-LINE KEYBOARD DISPLAY MODULE COVER NEMA4 W/O RESET
4-LINE KEYBOARD DISPLAY MODULE COVER NEMA4 WITH RESET
O.S. NO. DESCRIPTION
S7800A1001 2-LINE ENGLISH LANGUAGE
S7800A1142 2-LINE ENGLISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A1167 2-LINE SPANISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A2142 4-LINE ENGLISH/SPANISH/FRENCH (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
70-8911 13
7800 Series Product Selection Matrix
PRODUCT SELECTION MATRIX FOR RM7898 ON/OFF WITH PRE- AND PROGRAMMABLE POST-PURGE PRIMARY
RELAY MODULES FOR VALVE PROVING APPLICATIONS:
M23254C
SELECT A
SUBBASE
SELECT
OPTIONAL
COMPONENTS
KEYBOARD
DISPLAY
MODULE
COMMUNICATIONS
MISCELLANEOUS
SELECT A
RELAY
MODULE
O.S. NO.
Q7800A1005
Q7800B1003
Q7800B1011
DESCRIPTION
PANEL MOUNT
BURNER/WALL MOUNT
BURNER/WALL MOUNT WITH 3 KNOCKOUTS
DESCRIPTION
INTERMITTENT/INTERRUPTED PILOT AND PROOF OF CLOSURE
INTERMITTENT/INTERRUPTED PILOT WITH EARLY SPARK TERMINATION AND PROOF OF CLOSURE
SELECT A
PURGE
CARD
O.S. NO.
ST7800A1005
ST7800A1013
ST7800A1021
ST7800A1039
ST7800A1047
ST7800A1054
ST7800A1062
DESCRIPTION
TIMING: 2 SECOND
TIMING: 7 SECOND
TIMING: 10 SECOND
TIMING: 30 SECOND
TIMING: 40 SECOND
TIMING: 60 SECOND
TIMING: 90 SECOND
O.S. NO.
ST7800A1070
ST7800A1088
ST7800A1096
ST7800A1104
ST7800A1112
ST7800A1120
ST7800A1138
ST7800A1146
DESCRIPTION
TIMING: 2.5 MINUTE
TIMING: 4 MINUTE
TIMING: 6 MINUTE
TIMING: 9 MINUTE
TIMING: 12 MINUTE
TIMING: 15 MINUTE
TIMING: 22 MINUTE
TIMING: 30 MINUTE
120 VAC 50/60 HZ
RM7898A1000
RM7898A1018
O.S. NO.
R7847A1025
R7847A1033
R7847A1074
R7847A1082
R7847B1023
R7847B1031
R7847B1064
R7847B1072
R7847C1005
R7849A1015
R7849A1023
R7849B1013
R7849B1021
R7851C1008
R7852A1001
R7852B1009
R7861A1026
R7861A1034
R7886A1001
DESCRIPTION
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
CHECKING
NONE
NONE
NONE
NONE
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
DYNAMIC SELF-CHECK
NONE
NONE
AMPLICHECK®
AMPLICHECK®
DYNAMIC SELF-CHECK
NONE
AMPLICHECK®
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
USE WITH
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
C7012E, F
C7027, C7035
C7027, C7035
C7027, C7035
C7027, C7035
C7961E,F
C7915
C7915
C7061A, F
C7061A, F
C7076A, D
SELECT
A FLAME
AMPLIFIER
1.)
2.)
3.)
4.)
5.)
* FLAME ROD LEADWIRE RUNS GREATER THAN 50FT (1524 CM) OR PARALLEL C7012A,C.
O.S. NO.
S7810A1009
S7810M1003
DESCRIPTION
DATA CONTROLBUS® MODULE (IF NO KEYBOARD DISPLAY IS USED)
MODBUS MODULE
O.S. NO.
S7820A1007
S7830A1005
203541
203765
221729
50023821-001
204718B
50023821-002
205321B
221818A
221818C
204729A
204729C
DESCRIPTION
REMOTE RESET MODULE
EXPANDED ANNUNCIATIOR (120 VAC, 50/60 HZ)
DATA CONTROLBUS CONNECTOR, 5-WIRE
REMOTE DISPLAY MOUNTING BRACKET
DUST COVER, RELAY MODULE
KEYBOARD DISPLAY MODULE COVER, NEMA 4
KEYBOARD DISPLAY MODULE COVER, CLEAR
KEYBOARD DISPLAY MODULE COVER, NEMA 4, CLEAR WITH
RESET BUTTON
FLUSH DISPLAY MOUNTING KIT
EXTENSION CABLE, DISPLAY 5FT (1524MM)
EXTENSION CABLE, DISPLAY 10FT (3048MM)
4-LINE KEYBOARD DISPLAY MODULE COVER NEMA4 W/O RESET
4-LINE KEYBOARD DISPLAY MODULE COVER NEMA4 WITH RESET
O.S. NO. DESCRIPTION
S7800A1001 2-LINE ENGLISH LANGUAGE
S7800A1142 2-LINE ENGLISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A1167 2-LINE SPANISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A2142 4-LINE ENGLISH/SPANISH/FRENCH (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
14 70-8911
7800 Series Product Selection Matrix
PRODUCT SELECTION MATRIX FOR RM7838A MANUAL START WITH PURGE INDUSTRIAL PRIMARY RELAY MODULE:
M15527F
SELECT A
SUBBASE
SELECT
OPTIONAL
COMPONENTS
KEYBOARD
DISPLAY
MODULE
COMMUNICATIONS
MISCELLANEOUS
SELECT A
RELAY
MODULE
O.S. NO.
Q7800A1005
Q7800B1003
Q7800B1011
DESCRIPTION
PANEL MOUNT
BURNER/WALL MOUNT
BURNER/WALL MOUNT WITH 3 KNOCKOUTS
DESCRIPTION
INTERMITTENT PILOT, S7800A1001 KEYBOARD DISPLAY STANDARD
O.S. NO.
S7810A1009
S7810M1003
DESCRIPTION
DATA CONTROLBUS® MODULE (IF NO KEYBOARD DISPLAY IS USED)
MODBUS MODULE
O.S. NO.
S7820A1007
203541
203765
221729
50023821-001
204718B
50023821-002
205321B
221818A
221818C
DESCRIPTION
REMOTE RESET MODULE
DATA CONTROLBUS CONNECTOR, 5-WIRE
REMOTE DISPLAY MOUNTING BRACKET
DUST COVER, RELAY MODULE
KEYBOARD DISPLAY MODULE COVER, NEMA 4
KEYBOARD DISPLAY MODULE COVER, CLEAR
KEYBOARD DISPLAY MODULE COVER, NEMA 4, CLEAR WITH
RESET BUTTON
FLUSH DISPLAY MOUNTING KIT
EXTENSION CABLE, DISPLAY 5FT (1524MM)
EXTENSION CABLE, DISPLAY 10FT (3048MM)
SELECT A
PURGE
CARD
O.S. NO.
ST7800A1005
ST7800A1013
ST7800A1021
ST7800A1039
ST7800A1047
ST7800A1054
ST7800A1062
DESCRIPTION
TIMING: 2 SECOND
TIMING: 7 SECOND
TIMING: 10 SECOND
TIMING: 30 SECOND
TIMING: 40 SECOND
TIMING: 60 SECOND
TIMING: 90 SECOND
O.S. NO.
ST7800A1070
ST7800A1088
ST7800A1096
ST7800A1104
ST7800A1112
ST7800A1120
ST7800A1138
ST7800A1146
DESCRIPTION
TIMING: 2.5 MINUTE
TIMING: 4 MINUTE
TIMING: 6 MINUTE
TIMING: 9 MINUTE
TIMING: 12 MINUTE
TIMING: 15 MINUTE
TIMING: 22 MINUTE
TIMING: 30 MINUTE
120 VAC 50/60 HZ
RM7838A1014
O.S. NO.
R7847A1025
R7847A1033
R7847A1074
R7847A1082
R7847B1023
R7847B1031
R7847B1064
R7847B1072
R7847C1005
R7849A1015
R7849A1023
R7849B1013
R7849B1021
R7851C1008
R7852A1001
R7852B1009
R7861A1026
R7861A1034
R7886A1001
DESCRIPTION
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
CHECKING
NONE
NONE
NONE
NONE
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
DYNAMIC SELF-CHECK
NONE
NONE
AMPLICHECK®
AMPLICHECK®
DYNAMIC SELF-CHECK
NONE
AMPLICHECK®
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
USE WITH
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
C7012E, F
C7027, C7035
C7027, C7035
C7027, C7035
C7027, C7035
C7961E, F
C7915
C7915
C7061A, F
C7061A, F
C7076A, D
SELECT
A FLAME
AMPLIFIER
1.)
2.)
3.)
4.)
5.)
* FLAME ROD LEADWIRE RUNS GREATER THAN 50FT (1524 CM) OR PARALLEL C7012A,C.
O.S. NO. DESCRIPTION
S7800A1001 2-LINE ENGLISH LANGUAGE
S7800A1142 2-LINE ENGLISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A1167 2-LINE SPANISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A2142 4-LINE ENGLISH/SPANISH/FRENCH (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
70-8911 15
7800 Series Product Selection Matrix
PRODUCT SELECTION MATRIX FOR RM7838B MANUAL START INDUSTRIAL PROGRAMMER RELAY MODULE:
SELECT A
SUBBASE
SELECT
OPTIONAL
COMPONENTS
KEYBOARD
DISPLAY
MODULE
COMMUNICATIONS
MISCELLANEOUS
SELECT A
RELAY
MODULE
O.S. NO.
Q7800A1005
Q7800B1003
Q7800B1011
DESCRIPTION
PANEL MOUNT
BURNER/WALL MOUNT
BURNER/WALL MOUNT WITH 3 KNOCKOUTS
DESCRIPTION
SEMI-AUTOMATIC PROGRAMMER WITH:
S7800A1001 KEYBOARD DISPLAY STANDARD
S7800A1142 KEYBOARD DISPLAY STANDARD - HAS VALVE PROVING FEATURE
O.S. NO.
R7847A1025
R7847A1033
R7847A1074
R7847A1082
R7847B1023
R7847B1031
R7847B1064
R7847B1072
R7847C1005
R7849A1015
R7849A1023
R7849B1013
R7849B1021
R7851C1008
R7852A1001
R7852B1009
R7861A1026
R7861A1034
R7886A1001
DESCRIPTION
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
CHECKING
NONE
NONE
NONE
NONE
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
DYNAMIC SELF-CHECK
NONE
NONE
AMPLICHECK®
AMPLICHECK®
DYNAMIC SELF-CHECK
NONE
AMPLICHECK®
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
M15528F
O.S. NO.
S7810A1009
S7810M1003
DESCRIPTION
DATA CONTROLBUS® MODULE (IF NO KEYBOARD DISPLAY IS USED)
MODBUS MODULE
O.S. NO.
S7820A1007
S7830A1005
203541
203765
221729
50023821-001
204718B
50023821-002
205321B
221818A
221818C
DESCRIPTION
REMOTE RESET MODULE
EXPANDED ANNUNCIATIOR (120 VAC, 50/60 HZ)
DATA CONTROLBUS CONNECTOR, 5-WIRE
REMOTE DISPLAY MOUNTING BRACKET
DUST COVER, RELAY MODULE
KEYBOARD DISPLAY MODULE COVER, NEMA 4
KEYBOARD DISPLAY MODULE COVER, CLEAR
KEYBOARD DISPLAY MODULE COVER, NEMA 4, CLEAR WITH
RESET BUTTON
FLUSH DISPLAY MOUNTING KIT
EXTENSION CABLE, DISPLAY 5FT (1524MM)
EXTENSION CABLE, DISPLAY 10FT (3048MM)
USE WITH
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
C7012E, F
C7027, C7035
C7027, C7035
C7027, C7035
C7027, C7035
C7961E,F
C7915
C7915
C7061A, F
C7061A, F
C7076A, D
SELECT A
PURGE
CARD
O.S. NO.
ST7800A1005
ST7800A1013
ST7800A1021
ST7800A1039
ST7800A1047
ST7800A1054
ST7800A1062
DESCRIPTION
TIMING: 2 SECOND
TIMING: 7 SECOND
TIMING: 10 SECOND
TIMING: 30 SECOND
TIMING: 40 SECOND
TIMING: 60 SECOND
TIMING: 90 SECOND
O.S. NO.
ST7800A1070
ST7800A1088
ST7800A1096
ST7800A1104
ST7800A1112
ST7800A1120
ST7800A1138
ST7800A1146
DESCRIPTION
TIMING: 2.5 MINUTE
TIMING: 4 MINUTE
TIMING: 6 MINUTE
TIMING: 9 MINUTE
TIMING: 12 MINUTE
TIMING: 15 MINUTE
TIMING: 22 MINUTE
TIMING: 30 MINUTE
120 VAC 50/60 HZ
RM7838B1013*
RM7838B1021*
SELECT
A FLAME
AMPLIFIER
1.)
2.)
3.)
4.)
5.)
* ALARM SOUNDS UNTIL FLAME SENSED
* FLAME ROD LEADWIRE RUNS GREATER THAN 50FT (1524 CM) OR PARALLEL C7012A,C.
O.S. NO. DESCRIPTION
S7800A1001 2-LINE ENGLISH LANGUAGE
S7800A1142 2-LINE ENGLISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A1167 2-LINE SPANISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A2142 4-LINE ENGLISH/SPANISH/FRENCH (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
16 70-8911
7800 Series Product Selection Matrix
PRODUCT SELECTION MATRIX FOR RM7838C MANUAL START INDUSTRIAL PROGRAMMER RELAY MODULE:
SELECT A
SUBBASE
SELECT
OPTIONAL
COMPONENTS
KEYBOARD
DISPLAY
MODULE
COMMUNICATIONS
MISCELLANEOUS
SELECT A
RELAY
MODULE
O.S. NO.
Q7800A1005
Q7800B1003
Q7800B1011
DESCRIPTION
PANEL MOUNT
BURNER/WALL MOUNT
BURNER/WALL MOUNT WITH 3 KNOCKOUTS
DESCRIPTION
SEMI-AUTOMATIC PROGRAMMER WITH:
S7800A1001 KEYBOARD DISPLAY STANDARD
S7800A1142 KEYBOARD DISPLAY STANDARD - DEVICE HAS VALVE PROVING FEATURE
S7800A1001 KEYBOARD DISPLAY STANDARD
O.S. NO.
R7847A1025
R7847A1033
R7847A1074
R7847A1082
R7847B1023
R7847B1031
R7847B1064
R7847B1072
R7847C1005
R7849A1015
R7849A1023
R7849B1013
R7849B1021
R7851C1008
R7852A1001
R7852B1009
R7861A1026
R7861A1034
R7886A1001
DESCRIPTION
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
CHECKING
NONE
NONE
NONE
NONE
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
DYNAMIC SELF-CHECK
NONE
NONE
AMPLICHECK®
AMPLICHECK®
DYNAMIC SELF-CHECK
NONE
AMPLICHECK®
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
M18830F
O.S. NO.
S7810A1009
S7810M1003
DESCRIPTION
DATA CONTROLBUS® MODULE (IF NO KEYBOARD DISPLAY IS USED)
MODBUS MODULE
O.S. NO.
S7820A1007
S7830A1005
203541
203765
221729
50023821-001
204718B
50023821-002
205321B
221818A
221818C
DESCRIPTION
REMOTE RESET MODULE
EXPANDED ANNUNCIATIOR (120 VAC, 50/60 HZ)
DATA CONTROLBUS CONNECTOR, 5-WIRE
REMOTE DISPLAY MOUNTING BRACKET
DUST COVER, RELAY MODULE
KEYBOARD DISPLAY MODULE COVER, NEMA 4
KEYBOARD DISPLAY MODULE COVER, CLEAR
KEYBOARD DISPLAY MODULE COVER, NEMA 4, CLEAR WITH
RESET BUTTON
FLUSH DISPLAY MOUNTING KIT
EXTENSION CABLE, DISPLAY 5FT (1524MM)
EXTENSION CABLE, DISPLAY 10FT (3048MM)
USE WITH
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
C7012E,F
C7027, C7035
C7027, C7035
C7027, C7035
C7027, C7035
C7961E,F
C7915
C7915
C7061A, F
C7061A, F
C7076A, D
SELECT A
PURGE
CARD
O.S. NO.
ST7800C1003
ST7800C1011
ST7800C1029
ST7800C1037
ST7800C1045
ST7800C1052
DESCRIPTION
TIMING: 7 SECOND
TIMING: 20 SECOND
TIMING: 4 MINUTE
TIMING: 6 MINUTE
TIMING: 8 MINUTE
TIMING: 10 MINUTE
O.S. NO.
ST7800C1086
ST7800C1102
ST7800C1128
ST7800C1136
DESCRIPTION
TIMING: 16 MINUTE
TIMING: 20 MINUTE
TIMING: 24 MINUTE
TIMING: 30 MINUTE
120 VAC 50/60 HZ
RM7838C1004*
RM7838C1012*
RM7838C1020*+
SELECT
A FLAME
AMPLIFIER
1.)
2.)
3.)
4.)
5.)
* ALARM OUTPUT - LOCKOUT ONLY
+NORTH AMERICAN AND CE APPROVED
* FLAME ROD LEADWIRE RUNS GREATER THAN 50FT (1524 CM) OR PARALLEL C7012A,C.
O.S. NO. DESCRIPTION
S7800A1001 2-LINE ENGLISH LANGUAGE
S7800A1142 2-LINE ENGLISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A1167 2-LINE SPANISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A2142 4-LINE ENGLISH/SPANISH/FRENCH (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
70-8911 17
7800 Series Product Selection Matrix
PRODUCT SELECTION MATRIX FOR UL/CSA RM78XXG,M PROGRAMMER RELAY MODULE:
M15529F
SELECT A
SUBBASE
SELECT
OPTIONAL
COMPONENTS
KEYBOARD
DISPLAY
MODULE
COMMUNICATIONS
MISCELLANEOUS
SELECT A
RELAY
MODULE
O.S. NO.
Q7800A1005
Q7800B1003
Q7800B1011
DESCRIPTION
PANEL MOUNT
BURNER/WALL MOUNT
BURNER/WALL MOUNT WITH 3 KNOCKOUTS
O.S. NO.
R7847A1025
R7847A1033
R7847A1074
R7847A1082
R7847B1023
R7847B1031
R7847B1064
R7847B1072
R7847C1005
R7849A1015
R7849A1023
R7849B1013
R7849B1021
R7851C1008
R7852A1001
R7852B1009
R7861A1026
R7861A1034
R7886A1001
DESCRIPTION
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
CHECKING
NONE
NONE
NONE
NONE
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
DYNAMIC SELF-CHECK
NONE
NONE
AMPLICHECK®
AMPLICHECK®
DYNAMIC SELF-CHECK
NONE
AMPLICHECK®
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
O.S. NO.
S7810A1009
S7810M1003
DESCRIPTION
DATA CONTROLBUS® MODULE (IF NO KEYBOARD DISPLAY IS USED)
MODBUS MODULE
USE WITH
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
C7012E, F
C7027, C7035
C7027, C7035
C7027, C7035
C7027, C7035
C7961E, F
C7915
C7915
C7061A, F
C7061A, F
C7076A, D
SELECT A
PURGE
CARD
O.S. NO.
ST7800A1005
ST7800A1013
ST7800A1021
ST7800A1039
ST7800A1047
ST7800A1054
ST7800A1062
DESCRIPTION
TIMING: 2 SECOND
TIMING: 7 SECOND
TIMING: 10 SECOND
TIMING: 30 SECOND
TIMING: 40 SECOND
TIMING: 60 SECOND
TIMING: 90 SECOND
O.S. NO.
ST7800A1070
ST7800A1088
ST7800A1096
ST7800A1104
ST7800A1112
ST7800A1120
ST7800A1138
ST7800A1146
DESCRIPTION
TIMING: 2.5 MINUTE
TIMING: 4 MINUTE
TIMING: 6 MINUTE
TIMING: 9 MINUTE
TIMING: 12 MINUTE
TIMING: 15 MINUTE
TIMING: 22 MINUTE
TIMING: 30 MINUTE
120VAC 50/60 HZ
RM7800G1018
RM7840G1014
RM7840G1022
RM7800M1011
RM7840M1017
DESCRIPTION
MODULATING BURNER CONTROL, S7800A1001 KEYBOARD DISPLAY MODULE STANDARD
MODULATING BURNER CONTROL, WITHOUT KEYBOARD DISPLAY MODULE
MODULATING BURNER CONTROL, WITHOUT KEYBOARD DISPLAY MODULE - FOR VALVE PROVING
ON-OFF BURNER CONTROL, S7800A1001 KEYBOARD DISPLAY MODULE STANDARD
ON-OFF BURNER CONTROL, WITHOUT KEYBOARD DISPLAY MODULE
SELECT
A FLAME
AMPLIFIER
1.)
2.)
3.)
4.)
5.)
* FLAME ROD LEADWIRE RUNS GREATER THAN 50FT (1524 CM) OR PARALLEL C7012A,C.
O.S. NO.
S7820A1007
S7830A1005
203541
203765
221729
50023821-001
204718B
50023821-002
205321B
221818A
221818C
204729A
204729C
DESCRIPTION
REMOTE RESET MODULE
EXPANDED ANNUNCIATIOR (120 VAC, 50/60 HZ)
DATA CONTROLBUS CONNECTOR, 5-WIRE
REMOTE DISPLAY MOUNTING BRACKET
DUST COVER, RELAY MODULE
KEYBOARD DISPLAY MODULE COVER, NEMA 4
KEYBOARD DISPLAY MODULE COVER, CLEAR
KEYBOARD DISPLAY MODULE COVER, NEMA 4, CLEAR WITH RESET BUTTON
FLUSH DISPLAY MOUNTING KIT
EXTENSION CABLE, DISPLAY 5FT (1524MM)
EXTENSION CABLE, DISPLAY 10FT (3048MM)
4-LINE KEYBOARD DISPLAY MODULE COVER NEMA4 W/O RESET
4-LINE KEYBOARD DISPLAY MODULE COVER NEMA4 WITH RESET
O.S. NO. DESCRIPTION
S7800A1001 2-LINE ENGLISH LANGUAGE
S7800A1142 2-LINE ENGLISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A1167 2-LINE SPANISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A2142 4-LINE ENGLISH/SPANISH/FRENCH (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
18 70-8911
7800 Series Product Selection Matrix
PRODUCT SELECTION MATRIX FOR FM/IRI RM78XXE, L PROGRAMMER RELAY MODULE:
M34645
SELECT A
SUBBASE
SELECT
OPTIONAL
COMPONENTS
KEYBOARD
DISPLAY
MODULE
COMMUNICATIONS
MISCELLANEOUS
SELECT A
RELAY
MODULE
O.S. NO.
Q7800A1005
Q7800B1003
Q7800B1011
DESCRIPTION
PANEL MOUNT
BURNER/WALL MOUNT
BURNER/WALL MOUNT WITH 3 KNOCKOUTS
O.S. NO.
R7847A1025
R7847A1033
R7847A1074
R7847A1082
R7847B1023
R7847B1031
R7847B1064
R7847B1072
R7847C1005
R7849A1015
R7849A1023
R7849B1013
R7849B1021
R7851C1008
R7852A1001
R7852B1009
R7861A1026
R7861A1034
R7886A1001
DESCRIPTION
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
CHECKING
NONE
NONE
NONE
NONE
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
DYNAMIC SELF-CHECK
NONE
NONE
AMPLICHECK®
AMPLICHECK®
DYNAMIC SELF-CHECK
NONE
AMPLICHECK®
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
O.S. NO.
S7810A1009
S7810M1003
DESCRIPTION
DATA CONTROLBUS® MODULE (IF NO KEYBOARD DISPLAY IS USED)
MODBUS MODULE
USE WITH
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
C7012E, F
C7027, C7035
C7027, C7035
C7027, C7035
C7027, C7035
C7961E, F
C7915
C7915
C7061A, F
C7061A, F
C7076A, D
SELECT A
PURGE
CARD
O.S. NO.
ST7800A1005
ST7800A1013
ST7800A1021
ST7800A1039
ST7800A1047
ST7800A1054
ST7800A1062
DESCRIPTION
TIMING: 2 SECOND
TIMING: 7 SECOND
TIMING: 10 SECOND
TIMING: 30 SECOND
TIMING: 40 SECOND
TIMING: 60 SECOND
TIMING: 90 SECOND
O.S. NO.
ST7800A1070
ST7800A1088
ST7800A1096
ST7800A1104
ST7800A1112
ST7800A1120
ST7800A1138
ST7800A1146
DESCRIPTION
TIMING: 2.5 MINUTE
TIMING: 4 MINUTE
TIMING: 6 MINUTE
TIMING: 9 MINUTE
TIMING: 12 MINUTE
TIMING: 15 MINUTE
TIMING: 22 MINUTE
TIMING: 30 MINUTE
120VAC 50/60 HZ
RM7845A1001
DESCRIPTION
WITHOUT KEYBOARD DISPLAY (LESS IGNITION AND 15 SECOND MFEP PILOT TERMINALS)
SELECT
A FLAME
AMPLIFIER
1.)
2.)
3.)
4.)
5.)
* FLAME ROD LEADWIRE RUNS GREATER THAN 50FT (1524 CM) OR PARALLEL C7012A,C.
O.S. NO.
S7820A1007
S7830A1005
203541
203765
221729
50023821-001
204718B
50023821-002
205321B
221818A
221818C
204729A
204729C
DESCRIPTION
REMOTE RESET MODULE
EXPANDED ANNUNCIATIOR (120 VAC, 50/60 HZ)
DATA CONTROLBUS CONNECTOR, 5-WIRE
REMOTE DISPLAY MOUNTING BRACKET
DUST COVER, RELAY MODULE
KEYBOARD DISPLAY MODULE COVER, NEMA 4
KEYBOARD DISPLAY MODULE COVER, CLEAR
KEYBOARD DISPLAY MODULE COVER, NEMA 4, CLEAR WITH
RESET BUTTON
FLUSH DISPLAY MOUNTING KIT
EXTENSION CABLE, DISPLAY 5FT (1524MM)
EXTENSION CABLE, DISPLAY 10FT (3048MM)
4-LINE KEYBOARD DISPLAY MODULE COVER NEMA4 W/O RESET
4-LINE KEYBOARD DISPLAY MODULE COVER NEMA4 WITH RESET
O.S. NO. DESCRIPTION
S7800A1001 2-LINE ENGLISH LANGUAGE
S7800A1142 2-LINE ENGLISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A1167 2-LINE SPANISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A2142 4-LINE ENGLISH/SPANISH/FRENCH (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
70-8911 19
7800 Series Product Selection Matrix
PRODUCT SELECTION MATRIX FOR FM/IRI RM78XXE, L PROGRAMMER RELAY MODULE:
M15530G
SELECT A
SUBBASE
SELECT
OPTIONAL
COMPONENTS
KEYBOARD
DISPLAY
MODULE
COMMUNICATIONS
MISCELLANEOUS
SELECT A
RELAY
MODULE
O.S. NO.
Q7800A1005
Q7800B1003
Q7800B1011
DESCRIPTION
PANEL MOUNT
BURNER/WALL MOUNT
BURNER/WALL MOUNT WITH 3 KNOCKOUTS
O.S. NO.
R7847A1025
R7847A1033
R7847A1074
R7847A1082
R7847B1023
R7847B1031
R7847B1064
R7847B1072
R7847C1005
R7849A1015
R7849A1023
R7849B1013
R7849B1021
R7851C1008
R7852A1001
R7852B1009
R7861A1026
R7861A1034
R7886A1001
DESCRIPTION
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
3.0 SECOND FFRT
0.8 SECOND FFRT
3.0 SECOND FFRT
CHECKING
NONE
NONE
NONE
NONE
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
AMPLICHECK®
DYNAMIC SELF-CHECK
NONE
NONE
AMPLICHECK®
AMPLICHECK®
DYNAMIC SELF-CHECK
NONE
AMPLICHECK®
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
DYNAMIC SELF-CHECK
O.S. NO.
S7810A1009
S7810M1003
DESCRIPTION
DATA CONTROLBUS® MODULE (IF NO KEYBOARD DISPLAY IS USED)
MODBUS MODULE
USE WITH
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
FLAME ROD
FLAME ROD
FLAME ROD*
FLAME ROD*, C7012A, C
C7012E, F
C7027, C7035
C7027, C7035
C7027, C7035
C7027, C7035
C7961E, F
C7915
C7915
C7061A, F
C7061A, F
C7076A, D
SELECT A
PURGE
CARD
O.S. NO.
ST7800A1005
ST7800A1013
ST7800A1021
ST7800A1039
ST7800A1047
ST7800A1054
ST7800A1062
DESCRIPTION
TIMING: 2 SECOND
TIMING: 7 SECOND
TIMING: 10 SECOND
TIMING: 30 SECOND
TIMING: 40 SECOND
TIMING: 60 SECOND
TIMING: 90 SECOND
O.S. NO.
ST7800A1070
ST7800A1088
ST7800A1096
ST7800A1104
ST7800A1112
ST7800A1120
ST7800A1138
ST7800A1146
DESCRIPTION
TIMING: 2.5 MINUTE
TIMING: 4 MINUTE
TIMING: 6 MINUTE
TIMING: 9 MINUTE
TIMING: 12 MINUTE
TIMING: 15 MINUTE
TIMING: 22 MINUTE
TIMING: 30 MINUTE
120VAC 50/60 HZ
RM7800E1010
RM7840E1016
RM7800L1012
RM7840L1018
RM7800L1053
RM7840L1026
RM7800L1087
RM7840L1075
RM7800L1095
DESCRIPTION
ENERGY SAVING PURGE, S7800A1001 KEYBOARD DISPLAY STANDARD
ENERGY SAVING PURGE WITHOUT KEYBOARD DISPLAY
S7800A1001 KEYBOARD DISPLAY STANDARD
WITHOUT KEYBOARD DISPLAY
INTERMITTENT PILOT, S7800A1001 KEYBOARD DISPLAY STANDARD
INTERMITTENT PILOT WITHOUT KEYBOARD DISPLAY
S7800A1142 KEYBOARD DISPLAY STANDARD - WITH VALVE PROVING FEATURE
WITHOUT KEYBOARD DISPLAY - WITH VALVE PROVING FEATURE
S7800A1001 KEYBOARD DISPLAY STANDARD
SELECT
A FLAME
AMPLIFIER
1.)
2.)
3.)
4.)
5.)
* FLAME ROD LEADWIRE RUNS GREATER THAN 50FT (1524 CM) OR PARALLEL C7012A,C.
O.S. NO.
S7820A1007
S7830A1005
203541
203765
221729
50023821-001
204718B
50023821-002
205321B
221818A
221818C
204729A
204729C
DESCRIPTION
REMOTE RESET MODULE
EXPANDED ANNUNCIATIOR (120 VAC, 50/60 HZ)
DATA CONTROLBUS CONNECTOR, 5-WIRE
REMOTE DISPLAY MOUNTING BRACKET
DUST COVER, RELAY MODULE
KEYBOARD DISPLAY MODULE COVER, NEMA 4
KEYBOARD DISPLAY MODULE COVER, CLEAR
KEYBOARD DISPLAY MODULE COVER, NEMA 4, CLEAR WITH
RESET BUTTON
FLUSH DISPLAY MOUNTING KIT
EXTENSION CABLE, DISPLAY 5FT (1524MM)
EXTENSION CABLE, DISPLAY 10FT (3048MM)
4-LINE KEYBOARD DISPLAY MODULE COVER NEMA4 W/O RESET
4-LINE KEYBOARD DISPLAY MODULE COVER NEMA4 WITH RESET
O.S. NO. DESCRIPTION
S7800A1001 2-LINE ENGLISH LANGUAGE
S7800A1142 2-LINE ENGLISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A1167 2-LINE SPANISH LANGUAGE (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
S7800A2142 4-LINE ENGLISH/SPANISH/FRENCH (REQUIRED TO PROGRAM VALVE PROVING FEATURE)
20 70-8911
7800 Series Product Selection for legacy and competitor replacements
7800 Series Product Selection for legacy and competitor
replacements
Honeywell Device to be Replaced Replace With Amplifier
RA890E, F RM7895A R7847A
RA890G RM7895A R7849A
R4795A, D/W-R7290 AMP RM7895A
R4795A, D/W-R7289 AMP RM7895B R7847A
R7795A RM7895A R7849
R7795B RM7895A R7847
R7795C RM7895C R7849
R7796D RM7895C R7847
R4140P RM7895C R7847A or R7849A
R4140Y RM7895A
Fireye Device to be Replaced Replace With Amplifier
TFM1, 2, 3H RM7895A R7847A
UVM1, 2, 3, 3H R7849A
UVM5 RM7895C R7849A
IMPORTANT: For on-off, gas-fired systems, some authorities having jurisdiction prohibit the wiring of any limit or operating contacts in series with
the main fuel valve(s).
CONVERSION CHART FOR RM7895 120 VOLT ONLY
Q7800 TERMINAL L1 L2 3 4 6 7 8 9 10 21 F G
Programmer to be Converted
RA890 (All) 1a 2 c b, d 6 b 3d 5 4 — F G
R4795 (All) a 2 c 8, 7 1 6b 3 5 4 — F G
R7795A, B L1 L2 9 8 16 3 5 6 18 — F G
R7795C, D L1 L2 9 8 16 3 5 6 18 7 F G
R4140P L1 L2 A M 3 P 5 7 — 6 S1 S2
R4140Y L1 L2 9 8 4 3 6 7 5 — Fe G
Fireye: UVM/TFM (All models)/MII 1 1 A 8 7 6 3 5 4 — S2f S1
UVM-1 (Prior to 1968) a 2 A b, d 1 b 3 5 4 — Sf S
UVM-2 (Prior to 1968), All others a 2 A 8 1 6 3 5 4 — Sf S
a Connect power to terminal L1.
b If no airflow switch is used, jumper Q7800 terminal 6 to 7.
c Replace low voltage alarm (if used) with line voltage alarm. Connect alarm directly to Q7800 terminal 3.
d On power burners, identify burner motor wire on terminal 3 and connect it to Q7800 terminal 4.
e Select amplifier to match detector being used.
f On UVM models, the detector must be changed to a Honeywell C7027 or C7035.
REPLACEMENT DIRECTIONS:
1. Disconnect all power to programmer.
2. Remove old programmer from subbase (trade-in to Honeywell Authorized Flame Safeguard Distributor).
3. Mark all wires on subbase; i.e., wires connected to terminal “1” should be marked “1.” Disconnect wires as they are marked.
4. Remove old subbase.
5. Mount Q7800A Subbase.
6. Connect wires to subbase per attached cross reference. Pay close attention to footnotes. For example: to convert a Fireye UVM-2 to a RM7895,
the wire marked “A” would connect to terminal #9 on the Q7800. The wire marked “8” would connect to Q7800 terminal #8.
7. A superscript letter, such as “a” designates a footnote. Study these footnotes carefully.
8. Plug in the RM7895. Make sure you select the proper ST7800A Purge Timer and Detector for the application.
9. There are 2 wires on the amplifier section of the RM7895, which are used to select the desired trial for ignition timing and mode (lock-out or
recycle). Refer to the RM7895 instruction sheet (form 66-1090) for assistance with proper selection.
10. If a low voltage controller is used on the RA890 or UVM-1, remove it and replace it with a line voltage controller. The line voltage controller
should be connected in series with the limits.
11. If a low voltage airflow switch is used on the RM7895, it must be replaced with a line voltage airflow switch.
12. The following models are recommended for replacements:
70-8911 21
7800 Series Burner Controls
Commercial/Industrial Combustion Controls
7800 Series Burner Controls
EC7820 Primary Control Meeting European Community Timings
Integrated burner control for automatically fired gas, oil, or
combination, single burner atmospheric with fan applications. Has
automatic burner sequencing, flame supervising system status
indication, system or self-diagnostics, and troubleshooting.
• Access for external electrical voltage checks.
• Application flexibility and communication interface capability.
• Five LEDs provide sequence information.
• Five function Run/Test Switch. Interchangeable plug-in amplifiers.
• Local or remote annunciation of operation and fault information
(optional).
• Non-volatile memory retains history files and lockout status after loss
of power.
• Compatible with existing Honeywell flame detectors.
Application: Primary Control
Interlocks: Lockout
Preignition: Yes
PrePurge: Determined by ST7800A Purge Timer Card
PostPurge: 5 sec
Early Spark Termination: Yes, 5 sec
Required Components: Q7800A, B Universal Wiring Subbases.
R7847, R7849, R7861, or R7886 Flame Signal Amplifier. ST7800A
Plug-in Purge Timer Card.
Frequency: 60 Hz (±10%), 50 Hz
AirFlow Check: User selectable
Second Stage Pilot Valve: Intermittent
Vibration: 0.5 G environment
Shipping and Storage Temperature Range: -40°F to +140°F (-40°C
to +60°C)
Approximate, Dimensions: 5 in. wide x 5 in. high x 5 1/4 in. deep
with Q7800A Subbase x 6 3/32 in. deep with Q7800B Subbase
(127 mm wide x 127 mm high x 133 mm deep with Q7800A Subbase
x 155 mm deep with Q7800B Subbase)
Weight lb. (kg): 1 lb 10 oz (0.7 kg)
Approvals, Swiss RE: Acceptable
Approvals, Factory Mutual: Report No. 1V9AO.AF.
Approvals, Gastec/European: CE approved PIN-0063CT1466 against
EN 298:2012 under GAR 2016/426.
Dimensions in inches (millimeters)
5
5
BURNER CONTROL
5 1/2
M12821
1
1 REMOVE ONLY FOR TERMINAL TEST ACCESS.
Material Number Voltage Pilot Type Flame Establishing Period
- Main
Flame Establishing Period
- Pilot
Comments
EC7820A1026/U 220 to 240 Vac (+10,
-15%)
interrupted 5 sec, or 8 sec, or
Intermittent
5 sec or 10 sec 1 ignition attempt, Includes Modulation w/ Fan
Output
22 70-8911
7800 Series Burner Controls
EC7830; EC7850; RM7830; RM7850 Programming Control Meeting European
Community Timings
Microprocessor-based integrated burner control for full
modulation applications. Provides automatic burner sequencing,
flame supervision, system status indication, system or selfdiagnostics,
and troubleshooting.
• Access for external electrical voltage checks.
• Application flexibility and communication interface capability.
• Five LEDs provide sequence information.
• Five function Run/Test Switch.
• Interchangeable plug-in amplifiers.
• Local or remote annunciation of operation and fault information
(optional).
• Non-volatile memory retains history files and lockout status after loss
of power.
• Compatible with existing Honeywell flame detectors.
Application: Programming Control
Flame Establishing Period - Main: 3 sec, or 5 sec, or Intermittent
Flame Establishing Period - Pilot: 3 sec or 5 sec
Interlocks: Lockout
Preignition: Yes
PrePurge: Determined by ST7800A Purge Timer Card
Early Spark Termination: Yes, 5 sec
Required Components: Q7800A,B Universal Wiring Subbases.
R7847, R7849, R7861, or R7886 Flame Signal Amplifier. ST7800A
Plug-in Purge Timer Card.
AirFlow Check: User selectable
Second Stage Pilot Valve: Intermittent
Pilot Type: interrupted
Vibration: 0.5 G environment
Shipping and Storage Temperature Range: -40°F to +140°F (-40°C
to +60°C)
Approximate, Dimensions: 5 in. wide x 5 in. high x 5 1/4 in. deep
with Q7800A Subbase x 6 3/32 in. deep with Q7800B Subbase
(127 mm wide x 127 mm high x 133 mm deep with Q7800A Subbase
x 155 mm deep with Q7800B Subbase)
Weight lb. (kg): 1 lb 10 oz (0.7 kg)
Approvals, Swiss RE: Acceptable
Approvals, Factory Mutual: EC7830, EC7850, RM7830-Report No.
1V9AO.AF; RM7850-Report No. J.I. OYOA9.AF
Approvals, Gastec/European: CE approved PIN-0063CT1466 against
EN 298:2012 under GAR 2016/426..
Dimensions in inches (millimeters)
5
(127)
5 (127)
BURNER CONTROL
1
5-1/4 (133)
1 REMOVE ONLY FOR TERMINAL TEST ACCESS. M15532A
6-3/32 (155)
1
Material Number Voltage Frequency PostPurge Comments
EC7830A1033/U 220 to 240 Vac (+10, -15%) 60 Hz (±10%), 50 Hz 2 sec On/Off Power Burner
EC7830A1066/U 220 to 240 Vac (+10, -15%) 60 Hz (±10%), 50 Hz 15 sec On/Off Power Burner
EC7850A1072/U 220 to 240 Vac (+10, -15%) 60 Hz (±10%), 50 Hz 2 sec LHL-LF & HF Proven
EC7850A1080/U 220 to 240 Vac (+10, -15%) 60 Hz (±10%), 50 Hz 30 sec LHL-LF & HF Proven
EC7850A1122/U 220 to 240 Vac (+10, -15%) 60 Hz (±10%), 50 Hz 15 sec LHL-LF & HF Proven
RM7830A1029/U 120 Vac (+10, -15%) 50 Hz; 60 Hz (±10%) 30 sec On/Off Power Burner
RM7850A1001/U 120 Vac (+10, -15%) 50 Hz; 60 Hz (±10%) 2 sec LHL-LF & HF Proven
RM7850A1019/U 120 Vac (+10, -15%) 50 Hz; 60 Hz (±10%) 15 sec LHL-LF & HF Proven
70-8911 23
7800 Series Burner Controls
RM7800 Programmers
Microprocessor-based integrated burner control for automatically
fired gas, oil, coal or combination fuel single burner applications.
Provides safety, functional capability and features beyond
conventional controls.
• Functions include automatic burner sequencing, flame supervision,
system status indication, system or self-diagnostics and trouble
shooting.
• Access for external electrical voltage checks.
• Application flexibility and communication interface capability.
• Five LEDs provide sequence information.
• Five function Run/Test Switch.
• Interchangeable plug-in flame amplifiers.
• Local or remote annunciation of operation and fault information
(optional).
• Nonvolatile memory retains history files and lockout status after loss
of power.
• Compatible with existing Honeywell flame detectors.
• Includes Keyboard Display Module.
Application: Programming Control
Preignition: Yes
PrePurge: Determined by ST7800A Purge Timer Card
PostPurge: 15 sec
Early Spark Termination: Yes, 5 sec
Required Components: Q7800A, B Universal Wiring Subbases.
R7847, R7848, R7849, R7851, R7852, R7861, or R7886 Flame
Signal Amplifier. ST7800A Plug-in Purge Timer Card.
Frequency: 50 Hz; 60 Hz (±10%)
AirFlow Check: User selectable
Pilot Type: interrupted
Vibration: 0.5 G environment
Shipping and Storage Temperature Range: -40°F to +140°F (-40°C
to +60°C)
Approximate, Dimensions: 5 in. wide x 5 in. high x 5 1/4 in. deep
with Q7800A Subbase x 6 3/32 in. deep with Q7800B Subbase
(127 mm wide x 127 mm high x 133 mm deep with Q7800A Subbase
x 155 mm deep with Q7800B Subbase)
Weight lb. (kg): 1 lb 10 oz (0.7 kg)
Approvals, Underwriters Laboratories Inc.: Component Recognized,
File No. MP268; Guide No. MCCZ.
Approvals, FCC: FCC Part 15, Class B, Emissions.
Approvals, Swiss RE: Acceptable
Approvals, Factory Mutual: Report No. 1V9AO.AF.
Dimensions in inches (millimeters)
M15518B
BURNER CONTROL
POWER
PILOT
FLAME
MAIN
ALARM
RESET
5
(127)
5 (127)
1 REMOVE ONLY FOR TERMINAL TEST ACCESS.
1
5-1/4 (133)
1
6-3/32 (155)
MODULE WITH SUBBASE
Material Number Voltage Flame Establishing Period
- Main
Flame Establishing
Period - Pilot
Second Stage
Pilot Valve
Interlocks Comments
RM7800E1010/U 120 Vac (+10, -15%) 10 sec or 15 sec 4 sec or 10 sec Interrupted Lockout Includes S7800 Display, LHL-LF & HF
Proven
RM7800G1018/U 120 Vac (+10, -15%) 10 sec, or 15 sec, or 30 sec,
or Intermittent
4 sec or 10 sec selectable Running Includes S7800 Display, LHL-LF Proven
RM7800L1012/U 120 Vac (+10, -15%) 10 sec or 15 sec 4 sec or 10 sec Interrupted Lockout Includes S7800 Display, LHL-LF & HF
Proven
RM7800L1053/U 120 Vac (+10, -15%) 10 sec or Intermittent 4 sec or 10 sec Intermittent Lockout Includes S7800 Display, LHL-LF & HF
Proven
RM7800M1011/U 120 Vac (+10, -15%) 10 sec or Intermittent 4 sec or 10 sec Intermittent Running Includes S7800 Display, On/Off-LF
proven
24 70-8911
7800 Series Burner Controls
RM7800 Programmers with VPS
Integrated burner control for gas, oil, coal or combination fuel
single burner uses. With Valve Proving Feature. RM7800L comes
standard with S7800A1142 Keyboard Display.
• Functions include automatic burner sequencing, flame supervision,
system status indication, system or self-diagnostics and trouble
shooting.
• Access for external electrical voltage checks.
• Application flexibility and communication interface capability.
• Five LEDs provide sequence information. Power LED blinks fault
code on Lockout.
• Five function Run/Test Switch.
• Interchangeable plug-in flame amplifiers.
• Local or remote annunciation of operation and fault information
(optional).
• Nonvolatile memory retains history files and lockout status after loss
of power.
• Compatible with existing Honeywell flame detectors.
• RM7800 comes with S7800A1142 Keyboard Display Module.
• Keyboard required to setup Valve Proving Feature and change post
purge time.
Application: Programming Control w/VPS
Preignition: Yes
PrePurge: Determined by ST7800A Purge Timer Card
PostPurge: programmed with S7800A1142 display
Early Spark Termination: Yes, 5 sec
Required Components: Q7800A, B Universal Wiring Subbases.
R7847, R7848, R7849, R7851, R7852, R7861, or R7886 Flame
Signal Amplifier. ST7800A Plug-in Purge Timer Card.
Frequency: 50 Hz; 60 Hz (±10%)
AirFlow Check: User selectable
Pilot Type: interrupted
Vibration: 0.5 G environment
Shipping and Storage Temperature Range: -40°F to +140°F (-40°C
to +60°C)
Approximate, Dimensions: 5 in. wide x 5 in. high x 5 1/4 in. deep
with Q7800A Subbase x 6 3/32 in. deep with Q7800B Subbase
(127 mm wide x 127 mm high x 133 mm deep with Q7800A Subbase
x 155 mm deep with Q7800B Subbase)
Weight lb. (kg): 1 lb 10 oz (0.7 kg)
Approvals, Underwriters Laboratories Inc.: Component Recognized,
File No. MP268; Guide No. MCCZ.
Approvals, FCC: FCC Part 15, Class B, Emissions.
Approvals, Factory Mutual: Report No. 1V9AO.AF.
Dimensions in inches (millimeters)
M15518B
BURNER CONTROL
POWER
PILOT
FLAME
MAIN
ALARM
RESET
5
(127)
5 (127)
1 REMOVE ONLY FOR TERMINAL TEST ACCESS.
1
5-1/4 (133)
1
6-3/32 (155)
MODULE WITH SUBBASE
Material Number Voltage Flame Establishing
Period - Main
Flame Establishing
Period - Pilot
Second Stage
Pilot Valve
Interlocks Comments
RM7800L1087/U 120 Vac (+10, -15%) 10 sec or 15 sec 4 sec or 10 sec Interrupted Lockout Includes S7800A1142 Display, LHL-LF & HF Proven
70-8911 25
7800 Series Burner Controls
RM7823; EC7823 Flame Switch
Dimensions in inches (millimeters)
POWER
FLAME
ALARM
RESET
5
(127)
5 (127)
M2649
BURNER CONTROL
1 REMOVE ONLY FOR TERMINAL TEST ACCESS.
1
5-1/4 (133)
Microprocessor-based integrated flame switch for detecting a
flame using rectification, ultraviolet (UV) or infrared (IR) source.
Provides level of safety, functional capability and features beyond
conventional controls.
• Can be fitted with any 7800 Series Amplifier to provide relay action
from two single pole, double throw (SPDT) relays when flame is
present or not present. RM7823A and EC7823 are a flame detector
relays only.
• Suitable primary control must be used to provide safe-start check,
safety lockout, load switching and other functions required in flame
safeguard systems.
• Three LEDs to indicate power, flame and alarm.
• Access for external electrical voltage checks.
• Nonvolatile memory.
• Shutter drive output.
• Compatible with existing Honeywell flame detectors.
Application: Flame Switch
Required Components: Q7800A, B Universal Wiring Subbases.
R7847, R7848, R7849, R7851, R7852, R7861, or R7886 Flame
Signal Amplifier.
Vibration: 0.5 G environment
Shipping and Storage Temperature Range: -40°F to +140°F (-40°C
to +60°C)
Approximate, Dimensions: 5 in. wide x 5 in. high x 5 1/4 in. deep
with Q7800A Subbase x 6 3/32 in. deep with Q7800B Subbase
(127 mm wide x 127 mm high x 133 mm deep with Q7800A Subbase
x 155 mm deep with Q7800B Subbase)
Weight lb. (kg): 1 lb 13 oz (0.8 kg)
Approvals, Swiss RE: Acceptable,
GASTEC/European: CE approved against EN 298:2012 - PIN
0063CU1745 under GAR 2016/426
Comments: two SPDT outputs
Material Number Voltage Frequency Approvals, Underwriters
Laboratories Inc.
Approvals, CSA Approvals, FCC Approvals, Factory
Mutual
EC7823A1004/U 220 to 240 Vac
(+10, -15%)
60 Hz (±10%), 50 Hz Report No. OY0A9.AF.
RM7823A1016/U 120 Vac (+10,
-15%)
50 Hz; 60 Hz (±10%) Component Recognized,
File No. MP268; Guide
No. MCCZ.
Certified, File No.
LR95329-3.
FCC Part 15, Class B,
Emissions.
Report No. OX4A5.AF.
26 70-8911
7800 Series Burner Controls
RM7824 On-Off Primary Control
Dimensions in inches (millimeters)
5
(127)
5 (127)
M5872
BURNER CONTROL
1 REMOVE ONLY FOR TERMINAL TEST ACCESS.
1
5-1/4 (133)
24 Vdc microprocessor-based integrated burner control for
automatically fired gas, oil or combination fuel single burner
applications. Provides level of safety, functional capability and
features beyond the capacity of conventional controls.
• For use with R7824C Amplifier with C7024E, F Flame Detectors;
R7848A, B with C7015A Flame Detectors; R7851B with C7927
Flame Detectors; or R7852A, B with C7915 Flame Detectors.
• Functions include automatic burner sequencing, flame supervision,
system status indication, system or self diagnostics and
troubleshooting.
• Five LEDs provide sequence information.
• Selectable recycle or lockout on loss of flame.
• Shutter drive output for use with dynamic self-check flame detectors.
• Access for external electrical voltage checks.
• Plug-in flame amplifier.
• Nonvolatile memory retains history files and lockout status after loss
of power.
Application: Primary Control 24 Vdc
Required Components: Q7800A, B Universal Wiring Subbases.
R7824 or R7848 Flame Signal Amplifier.
Pilot Type: intermittent
Vibration: 0.5 G environment
Shipping and Storage Temperature Range: -40°F to +140°F (-40°C
to +60°C)
Approximate, Dimensions: 5 in. wide x 5 in. high x 5 1/4 in. deep
with Q7800A Subbase x 6 3/32 in. deep with Q7800B Subbase
(127 mm wide x 127 mm high x 133 mm deep with Q7800A Subbase
x 155 mm deep with Q7800B Subbase)
Weight lb. (kg): 1 lb 13 oz (0.8 kg)
Approvals, Underwriters Laboratories Inc.: Component Recognized,
File No. MP268; Guide No. MCCZ.
Approvals, FCC: FCC Part 15, Class B, Emissions.
Approvals, Swiss RE: Acceptable
Approvals, Factory Mutual: Report No. OX4A5.AF.
Material Number Voltage Flame Establishing Period - Main Flame Establishing Period - Pilot
RM7824A1006/U 24 Vdc (+10, -15%) Intermittent 4 sec or 10 sec
70-8911 27
7800 Series Burner Controls
RM7838A Manual Start Industrial Primary Control with Purge
Microprocessor-based integrated burner control for industrial
semi-automatically fired gas, oil, coal or combination fuel single
burner applications. Provides level of safety, functional capability
and features beyond conventional controls.
• Functions include purge, burner pilot startup, flame supervision,
system status indication, system or self diagnosis and
troubleshooting.
• Delays admission of fuel to combustion chamber until pilot flame
has been proven and then monitors the flame through the run period
while providing system status indication.
• Includes Keyboard Display Module.
• Five LEDs provide sequence information.
• Intermittent pilot valve.
• Interchangeable plug-in flame amplifier.
• Access for external electrical voltage checks.
• Nonvolatile memory retains history files and lockout status after loss
of power.
• Selectable pilot flame establishing period.
• Provides application flexibility and optional communication interface
capability.
• Compatible with existing Honeywell flame detectors.
Application: Semi Automatic Primary Control with Purge
Interlocks: Running
PrePurge: Determined by ST7800A Purge Timer Card
Required Components: Q7800A, B Universal Wiring Subbases.
R7847, R7848, R7849, R7851, R7852, R7861, or R7886 Flame
Signal Amplifier. ST7800A Plug-in Purge Timer Card.
Frequency: 50 Hz; 60 Hz (±10%)
Pilot Type: intermittent
Vibration: 0.5 G environment
Shipping and Storage Temperature Range: -40°F to +140°F (-40°C
to +60°C)
Approximate, Dimensions: 5 in. wide x 5 in. high x 5 1/4 in. deep
with Q7800A Subbase x 6 3/32 in. deep with Q7800B Subbase
(127 mm wide x 127 mm high x 133 mm deep with Q7800A Subbase
x 155 mm deep with Q7800B Subbase)
Weight lb. (kg): 1 lb 10 oz (0.7 kg)
Approvals, Underwriters Laboratories Inc.: Component Recognized,
File No. MP268; Guide No. MCCZ.
Approvals, Control Safety Devices: Acceptable: CSD-1
Approvals, FCC: FCC Part 15, Class B, Emissions.
Approvals, Swiss RE: Acceptable
Approvals, Factory Mutual: Report No. OX4A5.AF.
Dimensions in inches (millimeters)
M15518B
BURNER CONTROL
POWER
PILOT
FLAME
MAIN
ALARM
RESET
5
(127)
5 (127)
1 REMOVE ONLY FOR TERMINAL TEST ACCESS.
1
5-1/4 (133)
1
6-3/32 (155)
MODULE WITH SUBBASE
Material Number Voltage Flame Establishing Period - Main Flame Establishing Period - Pilot Comments
RM7838A1014/U 120 Vac (+10, -15%) Intermittent 4 sec or 10 sec Includes S7800 Display
28 70-8911
7800 Series Burner Controls
RM7838B, C Manual Start Industrial Programmers
Microprocessor-based integrated burner control for industrial
semi-automatically fired gas, oil, coal or combination fuel single
burner applications. Provides level of safety, functional capability
and features beyond conventional controls.
• Functions include purge, burner pilot startup, flame supervision,
system status indication, system or self diagnosis and
troubleshooting.
• Delays admission of fuel to combustion chamber until pilot flame
has been proven and then monitors the flame through the run period
while providing system status indication.
• Includes Keyboard Display Module.
• Five LEDs provide sequence information.
• Intermittent pilot valve.
• Interchangeable plug-in flame amplifier.
• Access for external electrical voltage checks.
• Nonvolatile memory retains history files and lockout status after loss
of power.
• Selectable pilot flame establishing period.
• Provides application flexibility and optional communication interface
capability.
• Compatible with existing Honeywell flame detectors.
Application: Semi Automatic Programming Control
Interlocks: Lockout
Preignition: Yes
Early Spark Termination: Yes, 5 sec
Frequency: 50 Hz; 60 Hz (±10%)
Pilot Type: interrupted
Vibration: 0.5 G environment
Shipping and Storage Temperature Range: -40°F to +140°F (-40°C
to +60°C)
Approximate, Dimensions: 5 in. wide x 5 in. high x 5 1/4 in. deep
with Q7800A Subbase x 6 3/32 in. deep with Q7800B Subbase
(127 mm wide x 127 mm high x 133 mm deep with Q7800A Subbase
x 155 mm deep with Q7800B Subbase)
Weight lb. (kg): 1 lb 10 oz (0.7 kg)
Approvals, Underwriters Laboratories Inc.: Component Recognized,
File No. MP268; Guide No. MCCZ.
Approvals, Control Safety Devices: Acceptable: CSD-1
Approvals, FCC: FCC Part 15, Class B, Emissions.
Approvals, Swiss RE: Acceptable
Approvals, Factory Mutual: Report No. OX4A5.AF.
Dimensions in inches (millimeters)
M15518B
BURNER CONTROL
POWER
PILOT
FLAME
MAIN
ALARM
RESET
5
(127)
5 (127)
1 REMOVE ONLY FOR TERMINAL TEST ACCESS.
1
5-1/4 (133)
1
6-3/32 (155)
MODULE WITH SUBBASE
Material Number Voltage Flame Establishing
Period - Main
Flame Establishing
Period - Pilot
PrePurge Required Components Approvals,
Gastec/European
Comments
RM7838B1013/U 120 Vac
(+10, -15%)
10 sec or Intermittent 4 sec or 10 sec Determined by
ST7800A Purge
Timer Card
Q7800A, B Universal Wiring
Subbases. R7847, R7848, R7849,
R7851, R7852, R7861, or R7886
Flame Signal Amplifier. ST7800A
Plug-in Purge Timer Card.
Includes
S7800 Display
RM7838C1004/U 120 Vac
(+10, -15%)
10 sec or Intermittent 4 sec or 10 sec Determined by
ST7800C Purge
Timer Card
Q7800A, B Universal Wiring
Subbases. R7847, R7848, R7849,
R7851, R7852, R7861, or R7886
Flame Signal Amplifier. ST7800C
Plug-in Purge Timer Card.
Includes
S7800 Display
RM7838C1020/U 120 Vac
(+10, -15%)
10 sec or Intermittent 4 sec or 10 sec Determined by
ST7800C Purge
Timer Card
Q7800A, B Universal Wiring
Subbases. R7847, R7848, R7849,
R7851, R7852, R7861, or R7886
Flame Signal Amplifier. ST7800C
Plug-in Purge Timer Card.
Gastec EN268
Report 1156791
Includes
S7800 Display
70-8911 29
7800 Series Burner Controls
RM7838B, C Manual Start Industrial Programmers with VPS
Integrated burner control for industrial semi-automatically fired
gas, oil, coal or combination fuel single burner applications.
Includes Valve Proving Feature with S7800A1142 Keyboard
Display.
• Functions include purge, burner pilot startup, flame supervision,
system status indication, system or self diagnosis and
troubleshooting.
• Delays admission of fuel to combustion chamber until pilot flame
has been proven and then monitors the flame through the run period
while providing system status indication.
• Includes S7800A1142 Keyboard Display Module.
• Five LEDs provide sequence information.
• Intermittent pilot valve.
• Interchangeable plug-in flame amplifier.
• Access for external electrical voltage checks.
• Nonvolatile memory retains history files and lockout status after loss
of power.
• Selectable pilot flame establishing period.
• Provides application flexibility and optional communication interface
capability.
• Compatible with existing Honeywell flame detectors.
• With Valve Proving Feature and Programmable Post Purge Time.
• Power LED blinks a fault code on system lockout.
Application: Semi Automatic Programming Control w/VPS
Interlocks: Lockout
Preignition: Yes
PostPurge: programmed with S7800A1142 display
Early Spark Termination: Yes, 5 sec
Frequency: 50 Hz; 60 Hz (±10%)
Pilot Type: interrupted
Vibration: 0.5 G environment
Shipping and Storage Temperature Range: -40°F to +140°F (-40°C
to +60°C)
Approximate, Dimensions: 5 in. wide x 5 in. high x 5 1/4 in. deep
with Q7800A Subbase x 6 3/32 in. deep with Q7800B Subbase
(127 mm wide x 127 mm high x 133 mm deep with Q7800A Subbase
x 155 mm deep with Q7800B Subbase)
Weight lb. (kg): 1 lb 10 oz (0.7 kg)
Approvals, Underwriters Laboratories Inc.: Component Recognized,
File No. MP268; Guide No. MCCZ.
Approvals, Control Safety Devices: Acceptable: CSD-1
Approvals, FCC: FCC Part 15, Class B, Emissions.
Approvals, Swiss RE: Acceptable
Approvals, Factory Mutual: Report No. OX4A5.AF.
Dimensions in inches (millimeters)
M15518B
BURNER CONTROL
POWER
PILOT
FLAME
MAIN
ALARM
RESET
5
(127)
5 (127)
1 REMOVE ONLY FOR TERMINAL TEST ACCESS.
1
5-1/4 (133)
1
6-3/32 (155)
MODULE WITH SUBBASE
Material Number Voltage Flame Establishing
Period - Main
Flame Establishing
Period - Pilot
PrePurge Required Components Comments
RM7838B1021/U 120 Vac
(+10, -15%)
10 sec or Intermittent 4 sec or 10 sec Determined by
ST7800A Purge Timer
Card
Q7800A, B Universal Wiring
Subbases. R7847, R7848, R7849,
R7851, R7852, R7861, or R7886
Flame Signal Amplifier. ST7800A
Plug-in Purge Timer Card.
Includes programmable
VPS (Valve Proving
Switch) check feature
and blinking LED fault
annunciation
RM7838C1012/U 120 Vac
(+10, -15%)
10 sec or Intermittent 4 sec or 10 sec Determined by
ST7800C Purge Timer
Card
Q7800A, B Universal Wiring
Subbases. R7847, R7848, R7849,
R7851, R7852, R7861, or R7886
Flame Signal Amplifier. ST7800C
Plug-in Purge Timer Card.
Includes programmable
VPS (Valve Proving
Switch) check feature
and blinking LED fault
annunciation
30 70-8911
7800 Series Burner Controls
RM7840 Programmers
Dimensions in inches (millimeters)
POWER
PILOT
FLAME
MAIN
ALARM
RESET
5
(127)
5 (127)
M5003B
(133)
BURNER CONTROL
REMOVE ONLY FOR TERMINAL TEST ACCESS.
1
5-1/4
1
Microprocessor-based integrated burner control for automatically
fired gas, oil, coal or combination fuel single burner applications.
Provides safety, functional capability and features beyond
conventional controls.
• Functions include automatic burner sequencing, flame supervision,
system status indication, system or self-diagnostics and
troubleshooting.
• Access for external electrical voltage checks.
• Application flexibility and communication interface capability.
• Five LEDs provide sequence information.
• Five function Run/Test Switch.
• Interchangeable plug-in flame amplifiers.
• Local or remote annunciation of RM7840 operation and fault
information.
• Nonvolatile memory retains history files and lockout status after loss
of power.
• Compatible with existing Honeywell flame detectors.
Application: Programming Control
Preignition: Yes
PrePurge: Determined by ST7800A Purge Timer Card
PostPurge: 15 sec
Early Spark Termination: Yes, 5 sec
Required Components: Q7800A, B Universal Wiring Subbases.
R7847, R7848, R7849, R7851, R7852, R7861, or R7886 Flame
Signal Amplifier. ST7800A Plug-in Purge Timer Card.
Voltage: 120 Vac (+10, -15%)
Frequency: 50 Hz; 60 Hz (±10%)
AirFlow Check: User selectable
Pilot Type: interrupted
Vibration: 0.5 G environment
Shipping and Storage Temperature Range: -40°F to +140°F (-40°C
to +60°C)
Approximate, Dimensions: 5 in. wide x 5 in. high x 5 1/4 in. deep
with Q7800A Subbase x 6 3/32 in. deep with Q7800B Subbase
(127 mm wide x 127 mm high x 133 mm deep with Q7800A Subbase
x 155 mm deep with Q7800B Subbase)
Weight lb. (kg): 1 lb 13 oz (0.8 kg)
Approvals, Underwriters Laboratories Inc.: Component Recognized,
File No. MP268; Guide No. MCCZ.
Approvals, Control Safety Devices: Acceptable: CSD-1
Approvals, FCC: FCC Part 15, Class B, Emissions.
Approvals, Swiss RE: Acceptable
Approvals, Factory Mutual: Report No. OX4A5.AF.
Material Number Interlocks Second Stage Pilot Valve Flame Establishing Period
- Main
Flame Establishing Period
- Pilot
Comments
RM7840E1016/U Lockout Interrupted 10 sec or 15 sec 4 sec or 10 sec LHL-LF & HF Proven
RM7840G1014/U Running selectable 10 sec, or 15 sec, or 30 sec,
or Intermittent
4 sec or 10 sec LHL-LF Proven
RM7840L1018/U Lockout Interrupted 10 sec or 15 sec 4 sec or 10 sec LHL-LF & HF Proven
RM7840L1026/U Lockout Intermittent 10 sec or Intermittent 4 sec or 10 sec LHL-LF & HF Proven
RM7840M1017/U Running Intermittent 10 sec or Intermittent 4 sec or 10 sec On/Off-LF Proven
70-8911 31
7800 Series Burner Controls
RM7840 Programmers with VPS
Dimensions in inches (millimeters)
POWER
PILOT
FLAME
MAIN
ALARM
RESET
5
(127)
5 (127)
M5003B
(133)
BURNER CONTROL
REMOVE ONLY FOR TERMINAL TEST ACCESS.
1
5-1/4
1
Integrated burner control for gas, oil, coal or combination fuel
single burner uses. Provides safety, functional capability and
features beyond normal controls. With Valve Proving Feature.
Requires S7800A1142 Keyboard Display.
• Functions include automatic burner sequencing, flame supervision,
system status indication, system or self-diagnostics and trouble
shooting.
• Access for external electrical voltage checks.
• Application flexibility and communication interface capability.
• Five LEDs provide sequence information. Power LED blinks fault
code on Lockout.
• Five function Run/Test Switch.
• Interchangeable plug-in flame amplifiers.
• Local or remote annunciation of operation and fault information
(optional).
• Nonvolatile memory retains history files and lockout status after loss
of power.
• Compatible with existing Honeywell flame detectors.
• RM7800 comes with S7800A1142 Keyboard Display Module.
• Keyboard required to setup Valve Proving Feature and change post
purge time.
Application: Programming Control w/VPS
Preignition: Yes
PrePurge: Determined by ST7800A Purge Timer Card
PostPurge: programmed with S7800A1142 display
Early Spark Termination: Yes, 5 sec
Required Components: Q7800A, B Universal Wiring Subbases.
R7847, R7848, R7849, R7851, R7852, R7861, or R7886 Flame
Signal Amplifier. ST7800A Plug-in Purge Timer Card.
Frequency: 50 Hz; 60 Hz (±10%)
AirFlow Check: User selectable
Second Stage Pilot Valve: selectable
Pilot Type: interrupted
Vibration: 0.5 G environment
Shipping and Storage Temperature Range: -40°F to +140°F (-40°C
to +60°C)
Approximate, Dimensions: 5 in. wide x 5 in. high x 5 1/4 in. deep
with Q7800A Subbase x 6 3/32 in. deep with Q7800B Subbase
(127 mm wide x 127 mm high x 133 mm deep with Q7800A Subbase
x 155 mm deep with Q7800B Subbase)
Weight lb. (kg): 1 lb 10 oz (0.7 kg)
Approvals, FCC: FCC Part 15, Class B, Emissions.
Material Number Voltage Flame Establishing
Period - Main
Flame Establishing
Period - Pilot
Interlocks Comments Approvals, Underwriters
Laboratories Inc.
Approvals, Factory
Mutual
EC7840L1014/U 220 to 240 Vac
(+10, -15%)
10 sec or 15 sec 4 sec or 10 sec Lockout Requires S7800A1142
Display, LHL-LF & HF
Proven
RM7840G1022/U 120 Vac (+10,
-15%)
10 sec, 15 sec, 30
sec, or Intermittent
4 sec or 10 sec Running Requires S7800A1142
Display, LHL-LF Proven
Component Recognized,
File No. MP268; Guide No.
MCCZ.
Report No. 1V9AO.AF.
RM7840L1075/U 120 Vac (+10,
-15%)
10 sec or 15 sec 4 sec or 10 sec Lockout Requires S7800A1142
Display, LHL-LF & HF
Proven
Component Recognized,
File No. MP268; Guide No.
MCCZ.
Report No. 1V9AO.AF.
32 70-8911
7800 Series Burner Controls
RM7845 Programmers
Dimensions in inches (millimeters)
POWER
PILOT
FLAME
MAIN
ALARM
RESET
5
(127)
5 (127)
M5003B
(133)
BURNER CONTROL
REMOVE ONLY FOR TERMINAL TEST ACCESS.
1
5-1/4
1
Microprocessor-based integrated burner control for automatically
fired gas, oil, coal or combination fuel single burner applications.
Provides safety, functional capability and features beyond
conventional controls.
• Functions include automatic burner sequencing, flame supervision,
system status indication, system or self-diagnostics and
troubleshooting.
• Access for external electrical voltage checks.
• Application flexibility and communication interface capability.
• Five LEDs provide sequence information.
• Five function Run/Test Switch.
• Interchangeable plug-in flame amplifiers.
• Local or remote annunciation of RM7840 operation and fault
information.
• Nonvolatile memory retains history files and lockout status after loss
of power.
• Compatible with existing Honeywell flame detectors.
Application: Programming Control
Interlocks: Lockout
Preignition: Yes
PrePurge: Determined by ST7800A Purge Timer Card
PostPurge: 15 sec
Required Components: Q7800A, B Universal Wiring Subbases.
R7847, R7848, R7849, R7851, R7852, R7861, or R7886 Flame
Signal Amplifier. ST7800A Plug-in Purge Timer Card.
Voltage: 120 Vac (+10, -15%)
Frequency: 50 Hz; 60 Hz (±10%)
AirFlow Check: User selectable
Pilot Type: interrupted
Vibration: 0.5 G environment
Shipping and Storage Temperature Range: -40°F to +140°F (-40°C
to +60°C)
Weight lb. (kg): 1 lb 13 oz (0.8 kg)
Approvals, Underwriters Laboratories Inc.: Component Recognized,
File No. MP268; Guide No. MCCZ.
Approvals, Control Safety Devices: Acceptable: CSD-1
Approvals, FCC: FCC Part 15, Class B, Emissions.
Approvals, Swiss RE: Acceptable
Approvals, Factory Mutual: Report No. 1V9AO.AF.
Material Number Flame Establishing Period - Main Flame Establishing Period - Pilot Comments
RM7845A1001/U 10 sec 4 sec or 10 sec LHL-LF & HF Proven
RM7885 Manual Start Industrial Primary Control
Dimensions in inches (millimeters)
POWER
PILOT
FLAME
MAIN
ALARM
RESET
5
(127)
5 (127)
M5003B
(133)
BURNER CONTROL
REMOVE ONLY FOR TERMINAL TEST ACCESS.
1
5-1/4
1
Microprocessor-based integrated burner control for industrial
semi-automatically fired gas, oil, coal, or combination fuel single
burner applications. Provides level of safety, functional capability
and features beyond conventional controls.
• Functions include flame supervision, system status indication,
system or self-diagnostics and troubleshooting.
• Adaptable to continuous firing, high-low or modulating firing rate for
semi-automatic burner sequencing.
• Operates with the following: Torch-ignited main burner or torchignited
pilot using S445A Start-Stop Station, or conventional knee or
foot operated station.
• Direct-ignition oil burner or electrically ignited pilot, using S445A
Start-Stop Station.
• Five LEDs provide sequence information.
• Nonvolatile memory.
• Flame signal check during standby.
• Shutter drive output.
• Compatible with existing Honeywell flame detectors.
• Terminal provided for external alarm to sound on flame failure.
Application: Semi Automatic Primary Control
Required Components: Q7800A, B Universal Wiring Subbases.
R7847, R7848, R7849, R7851, R7852, R7861, or R7886 Flame
Signal Amplifier.
Frequency: 50 Hz; 60 Hz (±10%)
Pilot Type: intermittent
Vibration: 0.5 G environment
Shipping and Storage Temperature Range: -40°F to +140°F (-40°C
to +60°C)
Weight lb. (kg): 1 lb 13 oz (0.8 kg)
Approvals, Underwriters Laboratories Inc.: Component Recognized,
File No. MP268; Guide No. MCCZ.
Approvals, FCC: FCC Part 15, Class B, Emissions.
Approvals, Swiss RE: Acceptable
Approvals, Factory Mutual: Report No. OX4A5.AF.
Material Number Voltage Flame Establishing Period - Main Flame Establishing Period - Pilot
RM7885A1015/U 120 Vac (+10, -15%) Intermittent 15 min
70-8911 33
7800 Series Burner Controls
RM7888 PLC Adaptable Primary Control
Dimensions in inches (millimeters)
BURNER CONTROL
POWER
PILOT
FLAME
MAIN
ALARM
RESET
SCROLL MODE
SAVE
5
(127)
5 (127)
M9494
5-1/4 (133)
1 REMOVE ONLY FOR TERMINAL TEST ACCESS.
1
Integrated burner control for industrial process semi-automatically
fired gas, oil, coal, or combination fuels for single and multiple
burner applications. PLC Adaptable.
• Functions include automatic burner startup sequencing, five user
selectable run sequences, four line-voltage sequence control
inputs, flame supervision, system status indication, system or selfdiagnostics
and troubleshooting.
• Requires a relay module, subbase, and amplifier for operation.
• Options include PC interface, keyboard display module, DATA
CONTROLBUS™ MODULE, remote display mounting, first-out
expanded annunciator, and COMBUSTION SYSTEM MANAGER™
software.
• Use with master system control which determines purge timing and
confirms air supply and air flow.
• Nonvolatile memory retains history files and sequencing status after
power loss.
• Optional remote reset capability.
• Five LEDs provide sequence information.
• Interchangeable plug-in flame amplifiers.
• Local or remote annunciation of operation and fault information.
Application: Primary Control - PLC Adaptable
Required Components: Q7800A, B Universal Wiring Subbases.
R7847, R7848, R7849, R7851, R7852, R7861, or R7886 Flame
Signal Amplifier.
Voltage: 120 Vac (+10, -15%)
Frequency: 50 Hz; 60 Hz (±10%)
Pilot Type: selectable
Vibration: 0.5 G environment
Shipping and Storage Temperature Range: -40°F to +140°F (-40°C
to +60°C)
Approximate, Dimensions: 5 in. wide x 5 in. high x 5 1/4 in. deep
with Q7800A Subbase x 6 3/32 in. deep with Q7800B Subbase
(127 mm wide x 127 mm high x 133 mm deep with Q7800A Subbase
x 155 mm deep with Q7800B Subbase)
Weight lb. (kg): 1 lb 10 oz (0.7 kg)
Approvals, Factory Mutual: Approved.
Material Number Flame Establishing Period - Main Flame Establishing Period - Pilot Comments
RM7888A1019/U 15 sec 4 sec Selectable sequences
RM7888A1027/U 15 sec 10 sec For 10 sec DSI applications, selectable
sequences
34 70-8911
7800 Series Burner Controls
RM7890 On-Off Primary Control with VPS
Dimensions in inches (millimeters)
POWER
PILOT
FLAME
MAIN
ALARM
RESET
5
(127)
5 (127)
M5003B
(133)
BURNER CONTROL
REMOVE ONLY FOR TERMINAL TEST ACCESS.
1
5-1/4
1
Integrated on/off primary burner control for automatically fired
gas, oil or combination fuel single burner applications. Contains
Valve Proving Feature. Requires S7800A1142 Display to program
VPS feature.
• Functions include automatic burner sequencing, flame supervision,
system status indication, system or self diagnostics and
troubleshooting.
• Subbase and amplifier are required for operation.
• Power LED blinks Fault Code on lockout.
• Options include PC interface, keyboard display module, DATA
CONTROLBUS™ MODULE, remote display module, first-out
expanded annunciator, and COMBUSTION SYSTEM MANAGER™
software.
• Five LEDs provide sequence information.
• Interchangeable plug-in flame amplifiers.
• Optional local or remote annunciation of operation and fault
information.
• Nonvolatile memory retains history files and sequencing status after
power loss.
• Optional remote reset capability.
• Optional report generation.
• Selectable relight or lockout on loss of flame.
• Contains Valve Proving Feature - require S7800A1142 Keyboard
Display (not provided) to set up.
Application: On-Off Primary Control w/VPS
Preignition: Yes
Required Components: Q7800A, B Universal Wiring Subbases.
R7847, R7848, R7849, R7851, R7852, R7861, or R7886 Flame
Signal Amplifier.
Voltage: 120 Vac (+10, -15%)
Frequency: 50 Hz; 60 Hz (±10%)
Pilot Type: intermittent
Vibration: 0.5 G environment
Shipping and Storage Temperature Range: -40°F to +140°F (-40°C
to +60°C)
Approximate, Dimensions: 5 in. wide x 5 in. high x 5 1/4 in. deep
with Q7800A Subbase x 6 3/32 in. deep with Q7800B Subbase
(127 mm wide x 127 mm high x 133 mm deep with Q7800A Subbase
x 155 mm deep with Q7800B Subbase)
Weight lb. (kg): 1 lb 13 oz (0.8 kg)
Approvals, Underwriters Laboratories Inc.: Component Recognized,
File No. MP268; Guide No. MCCZ.
Approvals, FCC: FCC Part 15, Class B, Emissions.
Approvals, Swiss RE: Acceptable
Approvals, Factory Mutual: Report No. OX4A5.AF.
Material Number Flame Establishing Period - Main Flame Establishing Period - Pilot Comments
RM7890A1056/U Intermittent 4 sec or 10 sec Includes programmable VPS (Valve Proving Switch) check feature
and blinking LED fault annunciation
RM7890B1048/U Intermittent 4 sec or 10 sec Includes Shutter Drive Capability, VPS (Valve Proving Switch)
check and blinking LED fault annunciation
70-8911 35
7800 Series Burner Controls
RM7890; EC7890 On-Off Primary Controls
Dimensions in inches (millimeters)
POWER
PILOT
FLAME
MAIN
ALARM
RESET
5
(127)
5 (127)
M5003B
(133)
BURNER CONTROL
REMOVE ONLY FOR TERMINAL TEST ACCESS.
1
5-1/4
1
Microprocessor-based integrated primary burner control for
automatically fired gas, oil or combination fuel single burner
applications. Provides level of safety, functional capability and
features beyond conventional controls.
• Functions include automatic burner sequencing, flame supervision,
system status indication, system or self diagnostics and
troubleshooting.
• Subbase and amplifier are required for operation.
• Options include PC interface, keyboard display module, DATA
CONTROLBUS™ MODULE, remote display module, first-out
expanded annunciator, and COMBUSTION SYSTEM MANAGER™
software.
• Five LEDs provide sequence information.
• Interchangeable plug-in flame amplifiers.
• Optional local or remote annunciation of operation and fault
information.
• Nonvolatile memory retains history files and sequencing status after
power loss.
• Optional remote reset capability.
• Optional report generation.
• Selectable relight or lockout on loss of flame.
Application: On-Off Primary Control
Flames Establishing Period - Main: Intermittent
Required Components: Q7800A, B Universal Wiring Subbases.
R7847, R7848, R7849, R7851, R7852, R7861, or R7886 Flame
Signal Amplifier.
Frequency: 50 Hz; 60 Hz (±10%)
Pilot Type: intermittent
Vibration: 0.5 G environment
Shipping and Storage Temperature Range: -40°F to +140°F (-40°C
to +60°C)
Approximate, Dimensions: 5 in. wide x 5 in. high x 5 1/4 in. deep
with Q7800A Subbase x 6 3/32 in. deep with Q7800B Subbase
(127 mm wide x 127 mm high x 133 mm deep with Q7800A Subbase
x 155 mm deep with Q7800B Subbase)
Weight lb. (kg): 1 lb 13 oz (0.8 kg)
Approvals, Swiss RE: Acceptable
Material Number Voltage Flame
Establishing
Period - Pilot
Approvals, Underwriters
Laboratories Inc.
Approvals, CSA Approvals, Factory
Mutual
Approvals, Gastec/
European
Comments
EC7890B1028/U 220 to 240 Vac
(+10, -15%)
4 or 10 sec Report No. 1V9AO.AF. CE approval model
EC7890B1028/U:
PIN-0063CT1466
against EN 298:2012
under GAR 2016/426
Includes Shutter
Drive Capability
RM7890A1015/U 120 Vac
(+10, -15%)
4 or 10 sec Component Recognized, File
No. MP268; Guide No. MCCZ.
Certified, File No.
LR95329-3.
Report No. OX4A5.AF.
RM7890A1031/U 120 Vac
(+10, -15%)
30 sec fixed Component Recognized, File
No. MP268; Guide No. MCCZ.
Certified, File No.
LR95329-3.
Report No. OX4A5.AF.
RM7890A1064/U 120 Vac
(+10, -15%)
4 or 10 sec Report No. 1D0A1.AF
RM7890B1014/U 120 Vac
(+10, -15%)
4 or 10 sec Component Recognized, File
No. MP268; Guide No. MCCZ.
Certified, File No.
LR95329-3.
Report No. OX4A5.AF. Includes Shutter
Drive Capability
RM7890B1030/U 120 Vac
(+10, -15%)
Fixed 4 or
10 sec PFEP
Component Recognized, File
No. MP268; Guide No. MCCZ.
Certified, File No.
LR95329-3.
Report No. OX4A5.AF. Includes Shutter
Drive Capability,
Alarm sounds when
Reset pushed.
RM7890B1055/U 120 Vac
(+10, -15%)
4 or 10 sec Component Recognized, File
No. MP268; Guide No. MCCZ.
Certified, File No.
LR95329-3.
Report No. OX4A5.AF. CE approval model
RM7890B1055/U:
PIN-0063CT1466
against EN 298:2012
under GAR 2016/426
Includes Shutter
Drive Capability
RM7890D1004/U 120 Vac
(+10, -15%)
15 or 30 sec Component Recognized, File
No. MP268; Guide No. MCCZ.
Certified, File No.
LR95329-3.
Report No. OX4A5.AF. Higher Flame Sensor
Voltage for Infra Red
Heater Applications
RM7890B1048 120 Vac
(+10, -15%)
4 or 10 sec Component Recognized, File
No. MP268; Guide No. MCCZ.
Report No. OX4A5.AF. Includes Shutter
Drive Capability
RM7890B1063 120 Vac
(+10, -15%)
4 or 10 sec Component Recognized, File
No. MP268; Guide No. MCCZ.
Includes Shutter
Drive Capability
36 70-8911
7800 Series Burner Controls
RA890 Replacement Options using RM/EC7890 Components
The Honeywell RA890 Protectorelay® Flame Safeguard product line has reached end-of-life and is going to go obsolete the first quarter of 2020.
Critical components have become difficult to source, limiting our ability to continue to build and offer this line to our customers.
Obsolete Products Replacement Products
The RA890 line of products will be replaced with comparable models in the RM/EC7800 SERIES*
Group A
RA890G1245/U, RA890F1304/U, RA890G1278/U, RA890G1040/U, RA890G1260/U,
RA890F1288/U.
Group A
6 replacement kits that covers most RA890 applications. (see below for details on
replacement kit sku numbers)
Group B
RA890F1296/U, RA890F1270/U, RA890F1411/U, RA890G1286/U, RA890G1229/U,
RA890F1346/U, RA890F1338/U, RA890F1718/U, RA890G1336/U, RA890F1387/U,
RA890F1478/U
Group B
Replacement components must be ordered separately. To replace the RA890
the following will be required: RM/EC7890 Flame Relay R78xx Flame Amplifier
Q7800F1004/U Subbase adapter please reference below charts for replacement
options
Replacement components
RA890 MODEL RELAY MODULE SUBBASE FLAME AMPLIFIER REPLACEMENT OPTIONS NOTES
RA890G1245/U EC7890B1028/U Q7800F1004/U R7849A1015/U RA890K1245/U Order KIT
RA890F1304/U EC7890B1028/U Q7800F1004/U R7847A1025/U RA890K1304/U Order KIT
RA890G1278/U EC7890B1028/U Q7800F1004/U R7849A1023/U RA890K1278/U Order KIT
RA890G1040/U RM7890B1063/U Q7800F1004/U R7849A1023/U RA890K1040/U Order KIT
RA890G1260/U RM7890A1015/U Q7800F1004/U R7849A1023/U RA890K1260/U Order KIT
RA890F1288/U RM7890A1015/U Q7800F1004/U R7847A1033/U RA890K1288/U Order KIT
RA890F1296/U EC7890B1028/U Q7800F1004/U R7847A1033/U Relay/Subbase/Flame Amp Order Separately
RA890F1270/U RM7890A1015/U Q7800F1004/U R7847A1025/U Relay/Subbase/Flame Amp Order Separately
RA890F1411/U RM7890B1063/U Q7800F1004/U R7847A1033/U Relay/Subbase/Flame Amp Order Separately
RA890G1286/U EC7890B1028/U Q7800F1004/U R7849A1023/U Relay/Subbase/Flame Amp Order Separately
RA890G1229/U RM7890A1015/U Q7800F1004/U R7849A1015/U Relay/Subbase/Flame Amp Order Separately
RA890F1346/U RM7890A1031/U Q7800F1004/U R7847A1033/U Relay/Subbase/Flame Amp Order Separately
RA890F1338/U RM7890A1031/U Q7800F1004/U R7847A1025/U Relay/Subbase/Flame Amp Order Separately
RA890F1718/U RM7890A1031/U Q7800F1004/U R7847A1033/U Relay/Subbase/Flame Amp Order Separately
RA890G1336/U RM7890A1015/U Q7800F1004/U R7849A1023/U Relay/Subbase/Flame Amp Order Separately
RA890F1387/U EC7890B1028/U Q7800F1004/U R7847A1033/U Relay/Subbase/Flame Amp Order Separately
RA890F1478/U RM7890A1015/U Q7800F1004/U R7847A1025/U Relay/Subbase/Flame Amp Order Separately
* Please contact your regional Honeywell sales representative for more information on replacement parts ordering process.
70-8911 37